If the WP ID is missing check the following:
1. Verify that you have configured the Serial Ports and GPS/NAV data sources correctly.
You should not have a GPS/NAV data source connected to Serial Port #1, it should only
connect to the ARINC module!
If you have the following it will not work !!
12. GPS/NAV 3 Data Source Serial Port #1
2. Verify the EFIS Serial Port #1 connections, Check the following connections:
EFIS DB-25 Function Wire 430W
10 Serial #1 TXD WHT 4001-57
22 Serial #1 RXD WHT/ORN 4001-56
If the CDI and VDI are missing the AF-ARINC module is not receiving ARINC data from the
430W. Check the following connections:
ARINC DB-25 Function 430W
12 ARINC GPS In 2-A 4001-46
24 ARINC GPS In 2-B 4001-47
4. Verify that the EFIS can send CRS/OBS data to 430W CRS
a. Select <-CRS-> on the EFIS knob.
As you turn the EFIS knob the OBS number on the 430W Test
Page should change. Once you stop turning the knob the OBS
setting will return to 150.
If the OBS did not change on the 430W the 430W is not receiving ARINC data from the AF-
ARINC module. Check the following connections:
ARINC DB-25 Function 430W
25 ARINC Out B 4001-49
13 ARINC Out A 4001-48