Diagram of Ination Chambers
3.3 Inating
IMPORTANT: Before inating, check to be sure that the kayak is completely assembled.
Inate your kayak in the following order. Failure to follow these instructions may cause
damage to your kayak. Do not over inate.
1. Inate chamber 1 until the AdvancedFrame™ Sport tube is rm to touch (2 psi ONLY).
2. Inate chamber 2 “oor” (using appropriate ing) twist valve open to inate and twist
closed when complete. Fill until rm. Do not over-inate! (1.0 psi ONLY).
3. Inate chamber 3 & 4 for desired deck li. Never over-inate! (1.0 psi ONLY).
4. Make sure all valves are closed tightly and properly.
5. Finally, Insert Plastic Bow and Stern forms into pocket on bow and stern.
CAUTION: Water temperature and weather will aect the air pressure of the kayak. In cold
weather your boat will lose some pressure as the air inside contracts. If this occurs, you may want
to add a bit more air to improve your kayak’s performance. However in hot weather, or prolonged
direct sunlight, the air inside will expand. You must let some air out of the appropriate chambers
to prevent the kayak from failing due to overpressure. You should avoid exposing your kayak to
extreme temperatures (hot or cold).