The LED on the ZDW120 will by default, turn ON when the load attached is turned ON. To make the LED
turn ON when the load attached is turned OFF instead, set parameter 3 to a value of 1.
• Parameter No: 3
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)
Invert Switch
To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.
• Parameter No: 4
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)
Ignore Start Level When Receiving Dim Commands
The ZDW120 can be set to ignore the start level that is part of the dim command, regardless of whether the
command itself is telling the dimmer to ignore the start level or not ignore the start level embedded in the
command (see Parameter 1). Setting parameter 5 to a value of 0 will cause the ZDW120 to dim or brighten
from the start level embedded in the command.
• Parameter No: 5
• Length: 1 Byte
• Valid Values = 0 or 1 (default 1)
Enable Shade Control Group 2
The ZDW120 can control shade control devices via its group 2 if this conguration parameter is set to 1.
• Parameter 14
• Length: 1 Byte
• Valid Values: 0 or 1 (default 0)
Enable Shade Control Group 3
The ZDW120 can control shade control devices via its group 3 if this conguration parameter is set to 1.
• Parameter 15
• Length: 1 Byte
• Valid Values: 0 or 1 (default 0)
LED Transmission Indication
The ZDW120 will icker its LED when it is transmitting to any of its 4 groups. This ickering can be set to
not icker at all (set to 0), to icker the entire time it is transmitting (set to 1), or to icker for only 1 second
when it begins transmitting (set to 2). By default, the ZDW120 is set to icker for only 1 second.
Parameter 19
Length: 1 Byte
Valid Values = 0 , 1, 2 (default 2)
Each Conguration Parameter can be set to its default setting by setting the default bit in the Conguration Set
command. See your controller’s instructions on how to do this (and if it supports it).
All Conguration commands will be reset to their default state when the ZDW120 is excluded from the Z-Wave
network by using the controller to reset the node (on the ZTH100 select “SETUP” and scroll to “RESET UNIT”).
SUC Support
There must be a Static Update Controller in your Z-Wave system for this feature to work. A Static Controller is
one that is not moved after addition to the network. The Static Controller can act as a gateway in the system,
since other nodes always know its position. The “always listening” advantage of the Static Controller is that
other nodes can transmit information frames to it whenever needed.
You can assign an “SUC Route” to the ZDW120. Refer to your Controller’s instructions on how to do this (if
it supports it). Assigning an SUC Route to the ZDW120 allows it to request an update of the Z-Wave devices
that are between it and the Z-Wave device to which it was trying to transmit. The ZDW120 will only request an
update when a transmission fails.