User Manual
Evolve Guest Controls LRM-20 Instructions
LRM-20
by Evolve Guest Controls
Proper Single Gang Installation
Using LRM-20’s standard full heat-sink (all tabs), the connected incandescent lamp load shall not exceed 500W.
If a tab is removed from one side of the LRM-20 unit, the connected incandescent lamp load must not exceed 400W.
If both tabs are removed from the LRM-20 unit, the connected incandescent lamp load must not exceed 300W.
Proper Dual Gang Installation
The connected incandescent lamp load must not exceed 400W for each of the two LRM-20 units.
Proper Triple Gang Installation
The connected incandescent lamp load must not exceed 300W for each of the three LRM-20 units.
Air Gap Switch
The LRM-20 has an air gap switch on the face (lower left), that when pulled out, completely removes the power available to
the load (simply turning the dimmer off does not). This enables the lamps that are controlled by the device to be changed
with minimal danger of electrical shock. The air gap switch must be pushed all the way back in for the dimmer to operate
the lamps again.
. Prepare the Controller to include a unit to the network by adding it to a group (method of adding a node to the network).
Refer to controller instructions.
LRM-20 Tap either the top or bottom of the LRM-20 switch once.
You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.
it may be that the Home ID and Node ID were not cleared from it after testing. You must first “RESET UNIT” with your
controller to remove it from the network. If using the EHC-100 select “SETUP” and scroll to “RESET UNIT”
Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If
removed from a group, it functions only as a repeater.
Local Control
The top or bottom of the LRM-20 switch can be used to carry out inclusion (add to a group), association, exclusion (remove
from group) or reset (remove from network).
Pushing the top or bottom of the switch, the LRM-20 allows the user to do the following:
• Turn ON, OFF, DIM or BRIGHTEN the load attached.
• Include or exclude the module from the EvolveNet network.
Configure to Control Shades or Window Coverings via EvolveNet network.• Control other EvolveNet enabled devices.
Also, when a controller prompts you to “Send Node ID” or to “Press Button on Unit”, quickly tap the top or bottom of the
switch once to satisfy those instructions.
• Tapping top of the switch turns the load attached ON.
• Tapping bottom of the switch turns the load attached OFF.• Pressing and holding the top of the switch will brighten
the load attached, and pressing and holding the bottom of the switch will dim the load. When OFF, pressing and
holding the bottom of the switch will cause the load will go to the minimum dim level.
Note: Upon restoration of power after a power loss, the LRM-20 returns to previous known state.
LED indication
The LED on the LRM-20 will turn on when the load attached is ON. However, the LED can be user configured to turn ON
when the load attached is OFF, if so desired, to act as a night light.
The LRM-20 will flicker its LED when it is transmitting to any of its groups. This can be changed if desired.
Remote Control
The LRM-20 will respond to BASIC and MULTILEVEL commands that are part of the EvolveNet system. Refer to your control-
ler’s instructions as to whether your controller can transmit those commands.
All On/All Off
The LRM-20 supports the ALL ON/ ALL OFF commands.