User's Manual

Evolve LRF-20 Instructions, Release 5.1
P/D 092610
EvolveNet
by EVOLVE GUEST CONTROLS
Radio Frequency (RF) Controlled, 120 VAC, Scene Capable,
Isolated Contact Fixture Module, Release 5.1, 300 Series
LRF-20 ISOLATED CONTACT FIXTURE MODULE
The LRF-20 Isolated Contact Fixture Module is a component of the Evolve lighting control system. Wire the Isolated
Contact Fixture Module according to the diagram above and program it from the Wireless Controller to operate
loads. Inclusion of this Switch on the EHC-100 Wireless Controller menu allows remote ON/OFF control of load
connected.
This Isolated Contact Fixture Module is designed to work with other Z-Wave enabled devices. Z-Wave nodes of
other types can be included on the network and will also act as repeaters if they support this function.
As part of a Z-Wave network, the LRF-20 will also act as a wireless repeater to insure that commands intended
for another device in the network are received. This is useful when the device would otherwise be out of the radio
range of the wireless controller.
There are no field repairable assemblies on this unit.. If service is needed, the unit must be returned where purchased.
DANGER! SHOCK HAZARD. Read and understand these instructions before installing. This device is intended
for installation in accordance with the National Electric code and local regulations in the United States, or the
Canadian Electrical Code and local regulations in Canada. It is recommended that a qualified electrician perform
this installation.
For indoor use only. Retain instructions for future use.
INSTALLATION
Wire this module in series with a (maximum) 20 amp load according to the diagram above.
AS101’s are required to be wired to the same line (or neutral) which is also wired to the master unit as well
as the load being controlled, and not wired to any other neutral. If multiple neutrals are tied together in one box,
separate the neutrals to preserve the integrity of the LRF-20 circuit. See the EHC-100 Wireless Controller operat-
ing instructions to include this module under the command of the Wireless Controller.
Fixture Mounted Configuration
Push the button on the face to configure the module to operate from the wireless controller (see EHC-100
instructions). With the Wireless Controller, the LRF-20 can be switched ON and OFF remotely, and can be
LRF-20

Summary of content (3 pages)