User Manual
LOM-15
102609
LOM-15
by EVOLVE GUEST CONTROLS
2
STEP 2. The LOM-15 must be in its permanently installed location. Tap the button on the face of the LOM-15 once
when your controller indicates (to include in the network).
STEP 3. You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.
NOTE: If you have trouble adding the LOM-15 to a group it may be that the Home ID and Node ID were not cleared from it after
testing. You must first “RESET UNIT” with your controller to remove it from the network. If using the IR-100 select “SETUP” and
scroll to “RESET UNIT”
Although adding it to a group includes it in the network, removing it from a group does not remove it from the network. If removed
from a group, it functions as a repeater only. “RESET UNIT” removes it from the network.
Receptacle Configuration
The LOM-15 Receptacle controls the ON and OFF of a load connected to the controlled outlet (see diagram on page one for
identification). The other outlet remains powered all the time. A button on the face of the receptacle is used to add the module
to the wireless network and be controlled from the wireless controller. With the Wireless Controller, the LOM-15 Receptacle can be
turned ON and OFF remotely, and can be included in groups that operate at the same time (a group can also be a single module), and
in scenes that set a lighting mood.
Local ON and OFF
When the button on the face of the LOM-15 is pressed, the power to the controlled outlet will turn on. When the button is pressed again,
the the controlled outlet will turn off.
Child Protection
The LOM-15 controlled outlet can be set in a child protect mode by the Wireless Controller. When this mode is active, a user will have
to press the button on the face 3 times rapidly to activate the attached load. The module operates normally when controlled by the
Wireless Controller..
Other functions
The button on the face of the LOM-15 Receptacle can be used to carry out inclusion (add to a group), association (operate simultane-
ously with other nodes), exclusion (remove from group) or reset (remove from network). This is described in more detail in the Advanced
Wireless Controller instructions on our web site.
The LOM-15 has a blue indicator LED. This LED will turn on when the controlled outlet is on and will turn off when the controlled outlet
is off. However, its behavior can be configured as a “night light” (LED ON when the controlled outlet is off). See Configuration section
below on how to do it.
ADVANCED OPERATION
Configuration
The LOM-15 supports the Configuration command.
The LOM-15 has some features that can be configured (If your controller supports it).
The LOM-15 can be configured to operate slightly differently than how it works when you first install it. You can use a HomePro IR-100
Wireless Controller to send Configuration commands (refer to the Setup Menu, Configuration section of the IR-100 instructions). Using
the Configuration command you can configure the following:
Set this parameter to 0 to have the blue indicator LED show state of controlled outlet (indicator ON = outlet ON).
Set this parameter to 1 to have indicator show the opposite state of controlled outlet (indicator ON = outlet OFF)
• Configuration Parameter No 3:
• Length: 1 Byte
• Valid Values: 0 or 1 (Default: 0)
SPECIFICATIONS
Power 120 VAC, 60 Hz
Maximum Load Resistive: 15 amps (1800 watts) maximum, 120 VAC