User's Manual

ACR122L-ACS Design Specification
Version 0.03 19/05/2010
Page
38
50
ACR122L
-
ACS
0 1 0 1 19 Units
0 1 1 0 21 Units
0 1 1 1 23 Units
1 0 0 0 129 Units
1 0 0 1 131 Units
1 0 1 0 133 Units
1 0 1 1 135 Units
1 1 0 0 145 Units
1 1 0 1 147 Units
1 1 1 0 149 Units
1 1 1 1 151 Units
Scrolling Direction: the Scrolling Direction
Bit1 Bit0 Scrolling Direction
0 0 From Left to Right
0 1 From Right to Left
1 0 From Top to Bottom
1 1 From Bottom to Top
Data Out: SW1 SW2.
Table 10.0C: Status Code
Results
SW1 SW2 Meaning
Success 90 00 The operation is completed successfully.
Error 63 00 The operation is failed.
5.11. Pseudo APDU for Pause LCD Scrolling
This APDU is used to Pause the LCD Scrolling set before
To resume the scrolling, send again the scrolling LCD command (5.10) to perform
Table 11.0A: Pause Scrolling Command Format (5 Bytes)
Command
Class INS P1 P2 Lc
Clear LCD 0xFF 0x00 0x6E 0x00 0x00
Data Out: SW1 SW2.
Table 11.0B: Status Code
Results
SW1 SW2 Meaning
Success 90 00 The operation is completed successfully.
Error
63 00 The operation is failed.