User's Manual
ACR122L
-
USB
-
ACS
6.4.4. Escape APDU for Buzzer Control
This APDU is used to control Buzzer
Table 5.0A: Buzzer Control Command Format (5 Bytes)
Command
Class
INS P1 P2 Lc Data In
(3 Bytes)
Buzzzer Control
0xFF 0x00
0x42
0x00
0x03
Buzzer Control
Data In: Buzzer Control
Table 5.0B: Buzzer On/Off Duration Control Format (4 Bytes)
Byte 0 Byte 1 Byte 2
T1 Duration
On State
(Unit = 100ms)
T2 Duration
Off State
(Unit = 100ms)
Number of
repetition
Data Out: SW1 SW2.
Table 5.0C: Status Code
Results
SW1 SW2 Meaning
Success 90 00 The operation is completed successfully.
Error
63 00 The operation is failed.
6.4.5. Escape APDU for Store Data one at Reader
This APDU is used to store a data up to 256 byte to the reader.
Table 5.0A: Store Data One Command Format (5 Bytes)
Command
Class
INS P1 P2 Lc Data
LenH
Data
LenL
Data
Buzzzer Control
0xFF 0x00
0x4a
0x00
0x00
data
Data LenH : The high byte of the data length
Data LenL : The low byte of the data length
Data Out: SW1 SW2.
Table 5.0C: Status Code
Results
SW1 SW2 Meaning
Success 90 00 The operation is completed successfully.
Error
63 00 The operation is failed.