User's Manual

APR. 25, 2003
ALA761 IN
11
4
H8/12 White/Red
Wire =
Factory Security
Disarm output
H8/12 White/Red
Wire =
Factory Security
Disarm output &
Factory Security
disarm with channel
3 on
Exit: Turn Ignition to 'ON' position, or leave it for 15 seconds. A 3 long chirps & 3 parking light flashes to
confirm exit.
Factory Security Disarm Output: It will output a 200mA (-) pulse whenever the system is disarmed. This
makes integration of this system into a vehicle with a factory alarm very simple.
Factory Security Disarm output & Factory Security disarm with channel 3 on: It will output a 200mA (-)
pulse whenever the system is disarmed or channel 3 is activated. This makes integration of this system into
a vehicle with a factory alarm very simple.
ALARM FEATURE “
IV
” PRORAMMING:
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in OFF position.
2. Push the Valet switch 8 times and hold it until four chirps with a long chirp is hearing then release the
valet switch. You are now in the Alarm feature ‘IV’ programming mode.
3. Press and release the transmitter button ‘A’ corresponding to the feature ‘A’ you want to program.
Press
T
ransmitte
r
Button
One Chirp /
LED one pulse
Factory Default
Setting
Two Chirps /
LED two pulse
Three Chirps /
LED three pulse
Four Chirps /
LED four pulse
1
H8/9 Gray Wire
Channel 3 Output =
1 second pulse
output for trunk
release.
H8/9 Gray Wire
Channel 3 Output =
Latched output
H8/9 Gray Wire
Channel 3 Output =
Latched output and
reset with ignition
“on”
H8/9 Gray Wire
Channel 3 Output =
Timer programming
(set to any interval
between 1 second
and 2 minutes.)
2.
H8/10 Black / Green
Wire Channel 4
Output =
Momentary output
H8/10 Black / Green
Wire Channel 4
Output =
Latched output
H8/10 Black / Green
Wire = Horn Output
H8/10 Black / Green
Wire Channel 4
Output =
Timer programming
(set to any interval
between 1 second
and 2 minutes.)
3
H8/11 Black / Red
Wire Channel 5
Output =
Momentary output
H8/11 Black / Red
Wire Channel 5
Output =
Latched output
H8/11 Black / Red
Wire Channel 5
Output =
Latched output and
reset with ignition
“on”
H8/11 Black / Red
Wire Channel 5
Output =
Timer programming
(set to any interval
between 1 second
and 2 minutes.)
4
H8/13 Black / Violet
Wire Channel 6
Output =
Momentary output
H8/13 Black / Violet
Wire Channel 6
Output =
Latched output
H8/13 Black / Violet
Wire Channel 6
Output =
Latched output and
reset with ignition
“on”
H8/13 Black / Violet
Wire Channel 6
Output =
Timer programming
(set to any interval
between 1 second
and 2 minutes.)
Exit: Turn Ignition to 'ON' position, or leave it for 15 seconds. A 3 long chirps & 3 parking light flashes to