5
#H5. 9 PIN BLACK CONNECTOR FOR INPUT CONNECTION:
6. Green Wire: Zone 3 / Negative Door Pin Trigger Input:
4. Blue Wire: Zone 2 / Instant Trigger Ground
7. Violet Wire: Zone 3 / Positive Door Pin Trigger
2. White / Violet Wire: (+) Positive Safety Shut Down Input for Brake switch.
3. Black/White Wire: (-) Neutral Safety Switch Input &
(-) Remote Start Toggle Switch Input
9. White / Red Wire: Tachometer Signal Input
+12V
1. White / Black Wire: (
-
) Negative Safety Shut Down Input for Hood pin switch
IMPORTANT NOTE: Directly connect the H5/3 BLACK/WHITE wire to the “GROUND” when this wire
is not used.
+12V
5. White / Green Wire: (-) Diesel Wait-To-Start Input
8. White / Blue Wire: (-) Instant Start and Turn Off Input
#H8. 10 PIN WHITE CONNECTOR FOR OUTPUT CONNECTION
4. White Wire: (-) 200mA Dome Light Control Output
7. Gray Wire: (-) 200mA Channel 3 (Trunk) Output
10. Orange Wire: (-) 500mA Grounded Output When Armed
1. Yellow Wire: (-) 200mA Ignition 3 Control Output
8. Pink Wire: (-) 200mA Programmable Output
1. 2 Steps Door Unlock Output (Factory Default Setting) or
2. Factory Security Disarm Signal Output or
3. Start Status (Shock Sensor By-Pass Control) Output
3. Brown / White Wire: (-) 200mA Programmable Output
1. Horn Output (Factory Default Setting) or
2. Factory Security Rearm Signal Output
6. Black / Gree n Wire: (-) 200mA Programmable Output
1. Channel 4 Programmable Output (Factory Default Setting) or
2. . Key Sensor By-Pass Output
2. Black / Violet Wire: (-)200mA Channel 6 Programmable Output
5. Black / Red Wire: (
-
) 200mA Channel 5 Programmable Output
9. Orange / White Wire: (-)200mA Grounded Output When Disarmed