User's Manual
APRIL /29/2004
400S 美 4
H7/8 Purple / Black wire – (-) 200mA Channel 4 Programmable Output –
(Factory default setting on momentary grounded)
This wire is built-in user-programmable timer output provides a ground through this wire. Press the
transmitter and buttons at the same time. You may program the built-in timer to send a ground
signal for any time interval between 1 second and 2 minutes. For instance, this timer output may be used to
turn on the headlight with the remote control. Also on certain BMW, Mercedes Benz, Jaguar and
Volkswagen cars, you can use this unique timed output to allow remote closure of all power window and
sunroof without the need for an external module!
H7/9 . Red / White wire – (-) 200mA Timer Control Channel 3 (Trunk) Output –
(Factory default setting on 1 second pulse grounded)
This will become a 1 second pulse ground by activate channel 3 on transmitter for two seconds, the current
capacity of this wire is 200 mA. This feature allows you to remote control trunk release or other electric
device. This output can also be programmed to provide the following type of output: 1 second pulse, latched,
timer control and pager. (See Alarm Feature III - 3 Programming)
H7/10. Black / White wire – (-) 200mA Dome Light Control Output –
This wire becomes grounded when the dome light controls circuit active. The current capacity of this wire is
200mA. This wire can control the operation of the interior lights. An optional 10 Amp relay can be used to this
system for interior lights operation.
a). Upon disarming, the interior lights will remain on for 30 seconds.
b). If the vehicle is violated, the interior light will flash for the same duration as the siren.
H4. 3 PIN DOOR LOCK HARNESS:
Blue
Wire
Green Wire
( - ) Lock Pulse
( + ) Unlock Pulse
( - ) Unlock Pulse
(+) Lock Pulse
INSTALL NEW DOOR LOCK MOTOR
Blue Wire
Green
+12V
30
86
87a
85
87
30
86
87a
85
87
3 Pin
Plug To
Alarm
NEGATIVE TRIGGER DOOR LOCK SYSTEM
Blue Wire Door Unlock
Green Wire Door Lock
Locking
Master
Switch
To Exiting
Door Lock Relay
POSITIVE TRIGGER DOOR LOCK SYSTEM
Blue Wire Door lock
Green Wire Door Unlock
Locking
Master
Switch
To Exiting
Door Lock Relay
+ 12V
+12V
Master Door
Lock Switch
X
X
Splice
Splice
Cut the Existing
Lock Wire
To Door
Lock
Motor
To Slave Door
Lock switches
Cut the Existing
Unlock Wire
3 Pin Plug
To Alarm
5-WIRE ALTERNATING DOOR LOCK
30
86
87a
85
87
30
86
87a
85
8
7
+12V
Green Wire
Blue Wire
VACUUM OPERATED CENTROL LOCKING
Green Wire
Blue Wire
+12V
X
Cut
Compressor
Door Switch
30
86
87a
85
87
30
86
87a
85
87
3 Pin
Plug To
Alarm