Service manual
SERVICE MANUAL
ENGLISH
Adnity
TM
17 ST, 20 ST, 20 D, X 20 D, X 20 C, X 24 D 9096982000(1)2007-02
15
SOLUTION/CLEAN WATER SUPPLY SYSTEM
SOLUTION/CLEAN WATER TANK AND SUPPLY SYSTEM CLEANING
Drive the machine to the appointed solution disposal area.
• (For Adnity
TM
20 D - X 20 D - X 20 C - X 24 D) Turn the ignition key (80) to “0”.
(For Adnity
TM
17 ST - 20 ST) Turn off the switches (71) and (73).
Empty the solution/clean water tank (20) with the hose (17).
Start the machine (as shown in the User Manual) and keep it running until the solution/clean water tank is completely
empty.
• (For Adnity
TM
20 D - X 20 D - X 20 C - X 24 D) Turn the ignition key (80) to “0”.
(For Adnity
TM
17 ST - 20 ST) Turn off the switches (71) and (73).
Clean the tank (20) with clean water.
Start the machine (as shown in the User Manual) and keep it running until the solution/clean water tank is completely
empty.
Clean the solution lter (see the following procedure).
SOLUTION FILTER CLEANING (For Adnity
TM
17 ST - 20 ST)
Drive the machine on a level oor.
Turn off the switches (71) and (73).
Close the solution tap (A) under the machine left lower side. The tap (A) is closed when it is on the position (B) and it is
open when it is on the position (C).
Remove the transparent cover (D), then remove the lter strainer (E). Clean and install them on the support (F).
NOTE
The lter strainer (E) must be correctly positioned on the housing (G) of the support (F).
Open the tap (A).
1.
2.
•
3.
4.
5.
•
6.
7.
8.
1.
2.
3.
4.
5.
E
G
F
E
D
A
C
B
S301520A