Distance to flammable material (see also illustration below)
Behind the stove
To the sides
Corner arrangement
To furniture
7.5 cm
40 cm
10 cm
100 cm
To secure access to inspection openings and enough air for the combustion, there needs to be a distance of
at least 8 cm to the wall behind. However, to ensure easy access during service and cleaning, we
recommend keeping a distance of min. 10 cm to the wall. You must be prepared to dismount the flue pipe
and turn the stove during the yearly inspection and by maintenance.
If the Aduro H2 is to be placed close to flammable material such as a wooden floor or carpet it must be
placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the Aduro H2
and 15 cm on each side measured from the combustion chamber opening.
Please ensure that all local rules and regulations are complied with, including CE marking of the exhaust
connector. Additionally, distance requirements to flammable material for the exhaust connector must be
respected.
2.2 Pipe connection
Aduro H2 leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the back,
remove the round circle from the rear cover at the upper rear of the stove and then exchange the exhaust
connector (located on the top outlet above the stove) with the cover plate (that covers the rear outlet). The
top outlet is finished with the plate that lies in the ash pan. We recommend that you place a thin gasket
between the flue pipe and exhaust branch. A flue pipe with an internal diameter of 150 mm should be used
for Aduro stoves. Aduro H2 is tested and approved for use with an uninsulated fluepipe of minimum 100 cm.
The Aduro H2 must be installed on a floor with the adequate load-bearing
capacity. If the existing construction does not meet this requirement,
appropriate adaptation measures must be taken (e.g. a load-distributing plate).