The chimney must be maintained and swept according to local rules.
The Aduro Hybrid stove must be inspected after one year for cleaning and adjustment. Hereafter,
maintenance must be conducted by an Aduro certified professional every other year or for every 2,000 kg
pellets burned.
6.5 Other maintenance
Gaskets
With time, gaskets around glass and door will wear. We recommend that you inspect them regularly. If
leakages appear, they must be replaced.
Combustion chamber
The fireproof tiles in the combustion chamber eventually wear out and should be replaced when the cracks
are more than 0.5 cm. The durability of the tiles depends on how often and how intensively the stove is used.
You can change the tiles yourself. They are available as a ready-to-use set. For further information, go to
www.aduroshop.com.
How do I remove the Bauart spring?
All Aduro stoves are fitted with a “Bauart” safety spring. The mechanism ensures that the door of the stove
closes automatically. The “Bauart” spring is only a law requirement in Germany.
How to remove it:
• If you wish to remove or replace the spring with a new one it is possible to cut the spring using a
pincer. It is advisable to hold the spring with pliers or cover it with a cloth or other device to absorb
the tension, as the pieces might spring out right after the cut.
• Please note that the spring is in tension when the door opens, so make sure to protect yourself
during fitting and removal.
• After that, close the hole in the oven with the enclosed self-tapping screw.
Cleaning the Aduro H2
The stove’s surface is treated with a heat-resistant Senotherm® paint, which will stay at its best just by being
vacuumed with a small, soft mouthpiece or dusted with a soft, dry cloth. Do not use spirit or other solvents, as
they will remove the paint.
The inside of the Aduro H2 and the flue pipe can be cleaned through the door or alternatively through the
cleaning aperture in the flue pipe/chimney. The upper fireproof tile (the exhaust deflector) can be removed.
To allow free access to the top of the Aduro H2 and the flue pipe, remove the exhaust deflector in steel.
Cleaning of the inside of the Aduro H2 and the flue pipe should be undertaken at least once a year, or more
Do not clean the hybrid stove with water. If the stove is exposed to moisture,
the stove may develop rust.