User Manual
68
Flame is low and brazier is overflown = the chimney draft is not sufficient
You can partly compensate for an inadequate chimney draft by increasing the fan speed on the hybrid stove.
This is done in the service menu of the app.
5. Control of Aduro H2
Aduro H2 has the following ALARM modes where pellet delivery must be stopped immediately:
• SMOKE SENSOR: smoke sensor defect.
• SHAFT SENSOR: shaft sensor defect.
• TERMO: shaft sensor too hot.
• DOOR CONTACT: door open.
• PELLET DAMPER: damper closed.
• EXIT: defect exit for external auger.
• FUEL: smoke temperature too low after more than an hour of operation – no fuel?
• LIGHTING: smoke temperature not reached after two attempts to light the fire.
• CO: CO (carbon monoxide) level is too high.
Here the ALARM will light red. When the cause of alarm has been rectified, the stove can be started by
pushing ON/OFF twice.