easier lighting of the firewood. When the logs have caught fire and the smoke temperature is about 280
degrees, the pellet supply will stop automatically.
The stove in pellet operation
When the stove is in pellet operation, you can always add firewood – you just have to remember to close the
door within 3 minutes. Open the door carefully and the pellet supply will stop and the ALARM flashes red.
Add firewood of the correct quality and respect the MAX load line. Close the door again. The stove will now
continue combustion of pellets. When the logs are burning and the smoke temperature is about 280 degrees,
the pellet supply stops automatically. After this, the stove will change to WOOD BURNING mode.
It may occur that the temperature rises above 300 degrees when using pellet operation on heat level 3. If this
happens, the pellet supply stops automatically and the stove will shift to wood burning mode. To avoid this,
reduce the amount of pellets at heat level 3. This is done in the service menu by choosing “auger”.
If you use the function "Heat Level" on the app and want the stove to restart automatically
on pellets when the wood has burned out, you can set the Aduro Hybrid on standby mode
with just 1 click on the button (see illustration). The stove will now be in standby mode and
await a smoke temperature below 100 degrees before it starts the pellet combustion and
ignites again. However, if you use the function "Desired Room Temperature", the Hybrid will
start automatically again when the smoke temperature is below 100 degrees.
IMPORTANT!
If the door to the combustion chamber is open for more than 3 minutes, the pellet combustion will shut
down and must be started again by pushing ON/OFF. The stove starts when the smoke temperature is
below 100 degrees. If the stove flashes green ON, it means that the stove will start, but is waiting for the
smoke temperature to be below 100 degrees C or timer.
When you want to switch off the pellet burner, push the ON/OFF button. If you open the stove door during
operation, the red ALARM will light. If you close the door before 3 minutes, the pellet burner goes back to
ON mode automatically.
3.4 How should I use my Aduro H2?
The Aduro H2 is intended for intermittent combustion. This means that each stoking should burn down to
embers before new logs are added.
In order to obtain the best possible combustion, you should regulate the effect/heat output with the fuel.
Burning small logs provides more powerful combustion than burning large logs as the surface area is greater
and more gas is released. The amount of wood in the combustion chamber is another factor that affects
combustion. The optimum combustion is achieved by adding two pieces of logs. If you want an enhanced
effect, you can add more logs. The nominal heat output is reached by burning approx. 1.5 kg per hour,
divided between 3 pieces with a length of approx. 21 cm.
If you experience problems lighting the fire or the fire dies after a short time, it can be due to the following
reasons:
• The firewood is not dry enough. The firewood should have a moisture content of max. 18%.
• There is a negative pressure in the house.