Brugsvejledning DA/NO (2-25) Bedienungsanleitung DE (26-50) User Manual EN (51-73) Eldningsinstruktion SE (74-96) Aduro H2 EN13240 - EN14785 - NS3058 aduro.dk / aduro.no / adurofire.de adurofire.com / adurofire.
EN Congratulations on your new Aduro H2 Stove! To get the best possible experience and benefit from your new Aduro H2, it is important that you read the user manual thoroughly before you install your Aduro H2 and start using it. Errors or incorrect settings can cause hazardous conditions and/or poor operation. For further information, please go to www.adurofire.com. At the inside of the bottom front door you can find the production number, the serial number, and the code for the Aduro Hybrid App.
1. General 1.1 Compliance Aduro H2 complies with the European Directive Ecodesign 2022, the EN13240 and EN14785 European standards as well as the NS3058 Norwegian standard and is thereby approved for installation and use in Europe. At the same time, the manufacturing process is subject to external quality control. DoP (Declaration of Performance) can be downloaded at www.adurofire.com/download.
• • • • • • • • • • Persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge can use the stove if they have been given supervision or instruction concerning use of the stove in a safe way and understand the hazards involved. The installation of the stove must be in accordance with legislation and regulations in the region or state. Any flammable objects must be kept at a safe distance from the product due to fire hazard in accordance to the product manual.
Ceramic igniter ✓ ✓ Energy efficiency 81% wood/ 87% pellets Energy efficiency index 122,3 Energy efficiency class A+ According to EN13240: Constant draft of 12 PA – read chapter 4.1 for further information. Ash pan Chimney draft Maximum combustion amount per hour: - Wood - Auger performance – pellets per hour Heat rating in buildings with - Optimum insulation - Average insulation - Inadequate insulation Electrical connection Pellet container capacity Approx. 3.1 kg Approx. 1.
Distance to flammable material (see also illustration below) Behind the stove To the sides Corner arrangement To furniture 7.5 cm 40 cm 10 cm 100 cm To secure access to inspection openings and enough air for the combustion, there needs to be a distance of at least 8 cm to the wall behind. However, to ensure easy access during service and cleaning, we recommend keeping a distance of min. 10 cm to the wall.
2.3 Connection to a brick chimney If the stove is being connected to a brick chimney, the rear outlet should be used, or a curved flue pipe via the top outlet. After measurement, a hole is made in the chimney in which the pipe sleeve is placed, and fireplace mortar is used to seal it in place. The stove is placed in position and the flue pipe is put in place. A thin gasket is placed between the flue pipe and the pipe sleeve to seal the joints.
2.5 Aduro Hybrid App It is possible to control Aduro H2 in three ways: 1. Through the control panel on the stove. 2. Through the app Aduro Hybrid and the Wi-Fi module “Aduro” in the near of the stove 3. Through the app Aduro Hybrid when the Wi-Fi module is connected to the router and connected to Aduro Cloud. When your stove is connected to Aduro Cloud, it can be controlled remotely. The app Aduro Hybrid is free and can be downloaded from App Store or Google Play.
The frontpage of the app shows: 1. Power status 2. Heat level 3. Smoke temperature 4. CO level (Safety measurement which measures whether there is smoke in the back of the system). A green bar is OK. If the bar reaches yellow, the hybrid stove will lower its heat level to 1. If the bar reaches red, the stove will turn off itself. The CO sensor is located by the pellet inlet to prevent the stove from firing when the chimney draft is not sufficient. The CO sensor could be affected by the pellets.
it is helpful for you as a user, but also helpful for us and the craftsmen, if something happens to the stove, or when it needs the yearly service visit from a professional. In Aduro Customer Service you can find a guideline on how to access the cloud. You can access the service center here. 3. Lighting a fire in the Aduro H2 You can light the fire using just pellets or light it manually with wood – or a combination where you put firewood in the combustion chamber and use the pellets to light the fire.
1: Fully open primary, secondary, and tertiary air inlet. This position can be maintained with the Aduro key, which must be placed in the two holes. 2: Closed primary air inlet, fully open secondary- and tertiary air inlet. 3: Closed primary air inlet, half way closed secondary air inlet and fully open tertiary air inlet. 4: Closed primary and secondary air inlet, fully open tertiary air inlet. 5: Regulator pushed all the way in. All air inlet closed (only used when burning wood pellets). 3.1.
3.2.1 How to operate Aduro-tronic When lighting with wood only When lighting a fire in the Aduro H2 for the first time, the maximum amount of primary air will be needed to light the fire. For that reason, the primary damper can be kept “forcibly open”. This is done by pulling the primary damper forward as far as possible and then fixing it with the Aduro Key (see illustration).
3.3.1 The first time a fire is lit During the first firing, which should be carried out using approximately 1 kg of wood, the stoking door must be left slightly open and must not be closed until the stove is cold. This is to prevent the sealing rope sticking to the stove. The first few times the Aduro H2 is used, there may be some smoke and unpleasant odours from the Aduro H2, which is fairly normal. This is caused by the heat-resistant paint hardening.
Brazier 3.3.4 Lighting the fire with pellets Before the pellet function of the stove is turned on, you should ensure that there are enough pellets underneath the brazier. You can do this by moving the brazier to the side. If there are pellets up to around 1 cm under the edge of the auger tube, there are enough pellets. You can now put the brazier back in place. Remember to check that it is placed correctly and fits tightly. Then, you can turn on the stove.
easier lighting of the firewood. When the logs have caught fire and the smoke temperature is about 280 degrees, the pellet supply will stop automatically. The stove in pellet operation When the stove is in pellet operation, you can always add firewood – you just have to remember to close the door within 3 minutes. Open the door carefully and the pellet supply will stop and the ALARM flashes red. Add firewood of the correct quality and respect the MAX load line. Close the door again.
• The smoke outlet from the outside may be blocked from sooth. This can occur after chimney sweeping. Control the smoke outlet. • The used amount of wood may have been too small. Therefore, the embers were too weak and cold to light the next load of wood. 3.5 Recommended fuels 3.5.1 Wood and wood briquettes Wood that has been stored indoors has a tendency to become too dry and will burn too quickly.
4. The chimney The optimum combustion is achieved at a constant chimney draft of 10-14 Pascal (Pa) measured in the flue pipe above the stove (when having a smoke exhauster). However, with natural draft (chimney without smoke exhauster) the draft in the chimney will be between 18-25 Pa when conditions are optimum. There are many factors that affect the chimney draft, including the outside temperature, wind strength, and surrounding buildings.
4.2 Chimney and Smoke If you experience smoke coming out of the stove or the start section of the smoke pipe, it could be due to certain weather conditions. On stormy or cold winter days or if the chimney has not been used in a while, a cold plug can be created in the chimney, meaning the natural draft will be at its minimum. If the chimney is cold and cold plugs are created, you may experience smoke leaks during the ignition and startup phase.
Flame is low and brazier is overflown = the chimney draft is not sufficient You can partly compensate for an inadequate chimney draft by increasing the fan speed on the hybrid stove. This is done in the service menu of the app. 5. Control of Aduro H2 Aduro H2 has the following ALARM modes where pellet delivery must be stopped immediately: • SMOKE SENSOR: smoke sensor defect. • SHAFT SENSOR: shaft sensor defect. • TERMO: shaft sensor too hot. • DOOR CONTACT: door open.
The development within phones and electronics continuously provides new possibilities and demands for updates and developments of the app. When you buy an Aduro Hybrid stove, updates of the app and control system are included 5 years after purchase. After this, charges may apply for updates. 6. Maintenance of the stove All maintenance and cleaning of the Aduro H2 should be carried out when the stove is cold and power disconnected. 6.
Brazier We recommend two types of maintenance during the week: a short cleaning while the stove is lit (cannot last more than 3 minutes because of the sensor in the door) and a thorough cleaning where the stove is turned off and cold. We recommend that you conduct the short cleaning 2 times a day and the thorough cleaning every 4 days. During the short cleaning, the stove must be cleaned under the brazier. We recommend that you use gloves.
The chimney must be maintained and swept according to local rules. The Aduro Hybrid stove must be inspected after one year for cleaning and adjustment. Hereafter, maintenance must be conducted by an Aduro certified professional every other year or for every 2,000 kg pellets burned. 6.5 Other maintenance Gaskets With time, gaskets around glass and door will wear. We recommend that you inspect them regularly. If leakages appear, they must be replaced.
frequently if necessary, depending on how often the Aduro H2 is used. This work can also be carried out by the chimney sweep or your local Aduro GO partner. Repairing the surface Aduro stoves are painted with a heat-resistant paint that can withstand temperatures up to 500 degrees. If the surface of the stove gets scratched or worn, it can easily be renewed using this type of paint. Everybody can repair the surface and obtain a perfect result.
• Consumable service parts (glass, gaskets, firebricks, handles, slides, painted surfaces, electrical igniter, sensors/switches, brazier, cast iron grate), which are subject to normal wear and tear. You can buy these parts in our webshop www.aduroshop.com. • Damages caused by electrical surcharge, (condensation) water in and around the chimney, too much or too little draught in the chimney and missing maintenance/cleaning. • Mounting or demounting in connection with warranty repairs.