Unit Installation NetVanta 1335 Series Hardware Installation Guide
36 Copyright © 2012 ADTRAN, Inc. 61700515E2-34D
5. UNIT INSTALLATION
The instructions and guidelines provided in this section cover hardware installation topics, such as mounting
options, supplying power to the unit, and installing option cards. These instructions are presented as follows:
• Tools Required on page 36
• Mounting Options on page 37
• Supplying Power to the Unit on page 38
• Installing Dial Backup and Network Interface Modules on page 39
• Installing a CompactFlash Card on page 41
For information on switch configuration for a specific application, refer to the configuration guides provided on
the ADTRAN Support Community
. For details on the command line interface (CLI), refer to the AOS
Command Reference Guide. All other related documents are also available online at
http://supportforums.adtran.com
.
Tools Required
The customer-provided tools required for the hardware installation of the NetVanta are:
• Ethernet cables
• Network cables (module dependent)
• DSX-1 cable (T1/FT1 + DSX-1 module only)
• DBU cable (dial backup functions require an optional DIM)
• Phillips-head screwdriver
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
The NetVanta 1335 Series is intended to be installed, maintained, and serviced by qualified
service personnel only and should be installed in a restricted access location as described
in UL/IEC 60950-1.
• PoE cables are intended for intrabuilding use only. Connecting an ADTRAN PoE unit
directly to PoE cables that run outside the building in which the unit is housed will void
the user's warranty and could create a fire or shock hazard.
• Ethernet cables are intended for intrabuilding use only. Connecting an ADTRAN unit
directly to Ethernet cables that run outside the building in which the unit is housed will
void the user's warranty and could create a fire or shock hazard. To connect an
ADTRAN unit to Ethernet cables that run outside the building, ADTRAN's Ethernet
Port Protection Device (EPPD) (P/N 1700502G1) must be connected between the unit
and the outside plant cable. Use of any Ethernet protector other than ADTRAN's for this
purpose will void the user's warranty.
To access the CLI of the NetVanta, you will also need a PC with VT100 terminal emulation
software and a console port cable. Instructions on how to access the CLI are available in
the quick start guide shipped with your unit or online on the ADTRAN Support Community
.