NetVanta 1335 Series Hardware Installation Guide 1700515G2#120 NetVanta 1335 with 120 VDC Power Supply 1700515G2#240 NetVanta 1335 with 240 VDC Power Supply 1700525E2 NetVanta 1335 PoE 1200861L1 NetVanta 56K/64K Network Interface Module 1202862L1 NetVanta T1/FT1 Network Interface Module 1202863L1 NetVanta T1/FT1 + DSX-1 Network Interface Module 1200872L1/1202872L1 NetVanta Dual T1 Network Interface Module 1200868E1/L1 NetVanta E1/FE1 Network Interface Module 1200878E1/L1 NetVanta E1/FE1 + G
Trademarks NetVanta 1335 Series Hardware Installation Guide Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.
NetVanta 1335 Series Hardware Installation Guide Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or endangerment to human life. 61700515E2-34D Copyright © 2012 ADTRAN, Inc.
Safety Instructions NetVanta 1335 Series Hardware Installation Guide Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. 2. Avoid using a telephone (other than a cordless type) during an electrical storm. There is a remote risk of shock from lightning.
NetVanta 1335 Series Hardware Installation Guide FCC-Required Information FCC-Required Information FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of Federal Communications Commission (FCC) rules and requirements adopted by America’s Carriers Telecommunications Association (ACTA). Each registered interface has a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX.
FCC Radio Frequency Interference Statement NetVanta 1335 Series Hardware Installation Guide FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
NetVanta 1335 Series Hardware Installation Guide Industry Canada Compliance Information Industry Canada Compliance Information Notice: The Industry Canada label applied to the product (identified by the Industry Canada logo or the “IC:” in front of the certification/registration number) signifies that the Industry Canada technical specifications were met. Notice: The REN for this terminal equipment is supplied in the documentation or on the product labeling/ markings.
Service and Warranty 8 NetVanta 1335 Series Hardware Installation Guide Copyright © 2012 ADTRAN, Inc.
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SFP Module Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Option Modules . . . . . . . . . . . . .
Table of Contents 10 NetVanta 1335 Series Hardware Installation Guide Copyright © 2012 ADTRAN, Inc.
List of Figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. NetVanta 1335 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 1335 PoE Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 1335 Rear Panel Layout . . . . . . . . . . . . . . . . . .
List of Figures 12 NetVanta 1335 Series Hardware Installation Guide Copyright © 2012 ADTRAN, Inc.
List of Tables Table 1. Front Panel LED Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table A-1. CONSOLE Port Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Table A-2. SFP Slot Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Table A-3. 10/100Base-T Ethernet Port Pinouts . . . . . . . . . . . . .
List of Tables 14 NetVanta 1335 Series Hardware Installation Guide Copyright © 2012 ADTRAN, Inc.
1. INTRODUCTION The NetVanta 1335 Series includes the NetVanta 1335 and NetVanta 1335 Power over Ethernet (PoE). In this document, the term NetVanta means all NetVanta 1335 Series products. If a statement only applies to one particular unit, the text refers to the unit individually. Additionally, unless otherwise specified, descriptions for a NetVanta 1335 Series device also applies to the PoE version of that device.
Physical Description 2. NetVanta 1335 Series Hardware Installation Guide PHYSICAL DESCRIPTION All NetVanta 1335 Series units are managed switches, plus multiservice routers housed in a 1U-high, rack-mountable metal enclosure. The NetVanta 1335 Series front panels contain 24 10/100Base-T Ethernet interfaces and two Gigabit Ethernet interfaces accessed via a fixed RJ-45 connector or small form-factor pluggable (SFP) slots for fiber connectivity.
NetVanta 1335 Series Hardware Installation Guide Physical Description After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
Physical Description NetVanta 1335 Series Hardware Installation Guide Table 1. Front Panel LED Descriptions LED STAT Port LEDs (i.e., 1 through 24, G1, G2, etc.) DBU WAN Power over Ethernet Status LEDs (PoE units only) 18 Color Indication Off Unit is not receiving power. Green (solid) Power is on and self-test passed. Green (flashing) On power up, the STAT LED flashes rapidly for five seconds, during which time the user may escape to boot mode from the CONSOLE port.
NetVanta 1335 Series Hardware Installation Guide Physical Description NetVanta 1335 Series Rear Panel Design The NetVanta 1335 Series rear panels are shown below. Refer to Appendix A on page 43 for pinouts. AC Power WAN-T1 DSX-1 DBU Figure 3. NetVanta 1335 Rear Panel Layout NetVanta 1335 Rear Panel Features NIM Option Slot The NIM option slot accepts a variety of NIM option modules (refer to Option Modules on page 21).
Product Specifications 3.
NetVanta 1335 Series Hardware Installation Guide 4. Option Modules OPTION MODULES The NetVanta 1335 Series support several option modules designed to meet a variety of networking requirements. The option modules include plug-in NIMs and plug-on DIMs. NIMs are cards that plug directly into the option module slot located on the rear of the base unit.
Option Modules NetVanta 1335 Series Hardware Installation Guide Network Interface Modules NetVanta 56K/64K NIM (P/N 1200861L1) The NetVanta 56K/64K NIM (see Figure 4) provides a digital data service (DDS) WAN interface for the NetVanta. This module provides a single 56K or 64K DDS network interface. Refer to Appendix A on page 43 for WAN-DDS and DBU connector pinouts. An optional DIM is required for dial backup applications. Figure 4.
NetVanta 1335 Series Hardware Installation Guide Option Modules NetVanta T1/FT1 NIM (P/N 1202862L1) The NetVanta T1/FT1 NIM (see Figure 5) provides a T1 WAN interface for the NetVanta. This module provides a full T1 or fractional T1 network interface. Refer to Appendix A on page 43 for WAN-T1 and DBU connector pinouts. An optional DIM is required for dial backup applications. WAN-T1 DBU Figure 5.
Option Modules NetVanta 1335 Series Hardware Installation Guide NetVanta T1/FT1 + DSX-1 NIM (P/N 1202863L1) The NetVanta T1/FT1 + DSX-1 NIM (see Figure 6) provides a T1 WAN interface for the NetVanta, a full or fractional T1 network interface, and a DSX-1 interface. Refer to Appendix A on page 43 for WAN-T1, DSX-1, and DBU connector pinouts. An optional DIM is required for dial backup applications. WAN-T1 DSX-1 DBU Figure 6.
NetVanta 1335 Series Hardware Installation Guide Option Modules NetVanta Dual T1 NIM (P/N 1200872L1/1202872L1) The NetVanta Dual T1 NIM (see Figure 7) provides two T1 WAN interfaces for the NetVanta. Refer to Appendix A on page 43 for WAN-T1 and DBU connector pinouts. An optional DIM is required for dial backup applications. WAN T1/1 WAN T1/2 DBU Figure 7.
Option Modules NetVanta 1335 Series Hardware Installation Guide NetVanta E1/FE1 NIM (P/N 1200868E1/L1) The NetVanta E1/FE1 NIM (see Figure 8) provides a WAN-E1 interface for the NetVanta meeting the requirements of ITU-T G.703/G.704. The module provides a single 2.048 Mbps network interface. Refer to Appendix A on page 43 for WAN-E1 and DBU connector pinouts. An optional DIM is required for dial backup applications. WAN-E1 DBU Figure 8.
NetVanta 1335 Series Hardware Installation Guide Option Modules NetVanta E1/FE1 + G.703 Drop NIM (P/N 1200878E1/L1) The NetVanta E1/FE1 + G.703 Drop NIM (see Figure 9) provides a single WAN-E1 interface (2.043 Mbps) with user-selectable TS0 assignment, and a G.703 drop port that may be used to drop and insert traffic to an E1 private branch exchange (PBX). Refer to Appendix A on page 43 for WAN-E1, G.703, and DBU connector pinouts. An optional DIM is required for dial backup applications. WAN-E1 G.
Option Modules NetVanta 1335 Series Hardware Installation Guide NetVanta Serial NIM (P/N 1200866E1) The NetVanta Serial NIM (see Figure 10) can be configured by the user as a V.35, X.21 (V.11), or EIA 530 interface. This module supports rates up to a maximum of 10 Mbps. An additional V.35 (ADTRAN P/N 1200873L1), X.21 (ADTRAN P/N 1200874L1), or EIA 530 (ADTRAN P/N 1200883L1) cable is required (refer to Caution, below). Refer to Appendix A on page 43 for serial connector and DBU connector pinouts.
NetVanta 1335 Series Hardware Installation Guide Option Modules NetVanta SHDSL NIM, Annex A (P/N 1200936E1) The NetVanta SHDSL NIM, Annex A (see Figure 11) provides a WAN SHDSL interface for the NetVanta. Refer to Appendix A on page 43 for WAN-SHDSL connector pinouts. WAN-SHDSL ANNEX A Figure 11. NetVanta SHDSL NIM, Annex A Features and Specifications Operating Mode Diagnostics • • • • • Line termination (CO) Network termination (CPE) SHDSL Interface • • • • • • Supported Standards: ITU-T G.991.
Option Modules NetVanta 1335 Series Hardware Installation Guide NetVanta SHDSL NIM, Annex B (P/N 1200937E1) The NetVanta SHDSL NIM, Annex B (see Figure 12) provides a WAN SHDSL interface for the NetVanta. Refer to Appendix A on page 43 for WAN-SHDSL connector pinouts. WAN-SHDSL ANNEX B Figure 12. NetVanta SHDSL NIM, Annex B Features and Specifications Operating Mode Diagnostics • • • • • Line termination (CO) Network termination (CPE) SHDSL Interface • • • • • • Supported Standards: ITU-T G.991.
NetVanta 1335 Series Hardware Installation Guide Option Modules NetVanta ADSL NIM, Annex A (P/N 1202869E1) The NetVanta ADSL NIM, Annex A (see Figure 13) adds ADSL capability to the NetVanta. The module provides a single ADSL, ADSL2, or ADSL2+ network interface to support rates up to 25 Mbps. Refer to Appendix A on page 43 for WAN-ADSL and DBU connector pinouts. An optional DIM is required for dial backup applications. WAN-ADSL DBU Figure 13.
Option Modules NetVanta 1335 Series Hardware Installation Guide NetVanta ADSL NIM, Annex B (P/N 1202889E1) The NetVanta ADSL NIM, Annex B (see Figure 14) adds ADSL capability to the NetVanta. Refer to Appendix A on page 43 for WAN-ADSL and DBU connector pinouts. An optional DIM is required for dial backup applications. WAN-ADSL DBU Figure 14. NetVanta ADSL NIM, Annex B Features and Specifications ADSL Interface Compliance • • • • ADSL over ISDN, Annex B Supported Standards: ITU G.992.1 (G.
NetVanta 1335 Series Hardware Installation Guide Option Modules Dial Backup Interface Modules NetVanta Analog Modem DIM (P/N 1200864L1) The Analog Modem DIM provides a modem with data rates up to 33.6 kbps for the NetVanta. This DIM is a plug-on card that connects to the NIM. For installation instructions, refer to Installing Dial Backup and Network Interface Modules on page 39. Features and Specifications Features • • Supported Standards: ITU V.
Option Modules NetVanta 1335 Series Hardware Installation Guide NetVanta ISDN BRI DIM (P/N 1200865L1) The NetVanta ISDN BRI DIM provides dial backup access to the public switched telephone network (PSTN) via Basic Rate ISDN for the NetVanta. This DIM is a plug-on module that connects to the NIM. For installation instructions, refer to Installing Dial Backup and Network Interface Modules on page 39.
NetVanta 1335 Series Hardware Installation Guide Option Modules NetVanta ISDN S/T DIM (P/N 1200875L1) The NetVanta ISDN S/T DIM provides dial backup access to the PSTN via Basic Rate ISDN for the NetVanta. This DIM is a plug-on module that connects to the NIM. For installation instructions, refer to Installing Dial Backup and Network Interface Modules on page 39.
Unit Installation 5. NetVanta 1335 Series Hardware Installation Guide UNIT INSTALLATION The instructions and guidelines provided in this section cover hardware installation topics, such as mounting options, supplying power to the unit, and installing option cards.
NetVanta 1335 Series Hardware Installation Guide Unit Installation Mounting Options The unit may be installed in rackmount, wallmount, or tabletop configurations. The following sections provide step-by-step instructions for rack mounting and wall mounting. Rack Mounting the NetVanta The NetVanta is a 1U-high, rack-mountable unit that can be installed into a 19-inch equipment rack. The following steps guide you in mounting the NetVanta into a rack.
Unit Installation NetVanta 1335 Series Hardware Installation Guide Instructions for Wall Mounting the NetVanta Step Action 1 Remove the mounting ears. Rotate them 90 degrees so that the portion of the bracket with the mounting holes is flush with the bottom of the chassis. Reattach the mounting ears to the chassis (see Figure 15). 2 Decide on a location for the NetVanta. All NetVanta 1335 Series units are mounted with the front panel facing down (see Figure 15).
NetVanta 1335 Series Hardware Installation Guide Unit Installation Installing Dial Backup and Network Interface Modules The DIM plugs on to the NIM. The NIM is then installed into the rear panel option module slot. The following tables list the installation steps. Also, see Figure 16 below and Figure 17 on page 40. For NetVanta modules with outside plant connections, ensure that all cables are removed from the module before installing or removing it from the NetVanta chassis.
Unit Installation NetVanta 1335 Series Hardware Installation Guide Instructions for Installing the NIMs Step Action 1 Remove power from the unit. 2 Use a screwdriver to remove the cover plate from the appropriate option slot in the NetVanta base unit. 3 Slide the option module into the option slot until the module is firmly seated against the chassis. 4 Secure the pins at both edges of the module. 5 Connect the cables to the associated device(s). 6 Restore power to the unit.
NetVanta 1335 Series Hardware Installation Guide Unit Installation Installing a CompactFlash Card The CompactFlash slot supports only ADTRAN-provided 1 GB CompactFlash cards. Follow these instructions when installing a card The CompactFlash card is hot-swappable and can be inserted or removed while power is applied to the unit. Instructions for Installing a CompactFlash Card Step Action Slide the module into the CompactFlash slot until the card is firmly seated against the chassis.
Unit Installation 42 NetVanta 1335 Series Hardware Installation Guide Copyright © 2012 ADTRAN, Inc.
APPENDIX A. CONNECTOR PIN DEFINITIONS The following tables provide the pin assignments for the base unit, NIMs, and DIMs. Base Unit Pinouts Table A-1. CONSOLE Port Pinouts Pin Name Description 1 DCD 2 RD Receive Data (output) 3 TD Transmit Data (input) 4 DTR 5 SG 6 DSR 7 — 8 CTS 9 — Data Carrier Detect (output) Data Terminal Ready (input) Signal Ground Data Set Ready Tied to pin 1 (output) Unused Clear to Send Tied to pin 1 (output) Unused Table A-2.
Appendix A. Connector Pin Definitions NetVanta 1335 Series Hardware Installation Guide Table A-3. 10/100Base-T Ethernet Port Pinouts Pin Name Description 1 TX1 Transmit Positive 2 TX2 Transmit Negative 3 RX1 Receive Positive 4, 5 — 6 RX2 7, 8 — Unused Receive Negative Unused Table A-4.
NetVanta 1335 Series Hardware Installation Guide Appendix A. Connector Pin Definitions Network Interface Module Pinouts Table A-5. WAN-T1 Connector Pinouts Pin Name Description 1 R1 Receive data from the network–Ring 1 2 T1 Receive data from the network–Tip 1 3 — Unused 4 R Transmit data toward the network–Ring 5 T Transmit data toward the network–Tip 6-8 — Unused Table A-6.
Appendix A. Connector Pin Definitions NetVanta 1335 Series Hardware Installation Guide Table A-8. G.703 Connector Pinouts Pin Name Description 1 R Transmit data toward the DTE–Ring 2 T Transmit data toward the DTE–Tip 3 — Unused 4 R1 Receive data from the DTE–Ring 1 5 T1 Receive data from the DTE–Tip 1 6-8 — Unused Table A-9.
NetVanta 1335 Series Hardware Installation Guide Appendix A. Connector Pin Definitions Table A-11. Serial to Cable Connector Pinouts Serial Pin V.35 Pin X.21 Pin EIA 530 Pin Name 1 P 2 2 TD_A 2 U N/A 24 ETC_A 3 Y N/A 15 TCLK_A 4 V 6 17 RCLK_A 5 R 4 3 RD_A 6 F N/A 8 DCD_A 7 H N/A 20 DTR_A 8 C 3 4 RTS_A 9 N/A 10 19 RTS_B (V.11 only) 10 N/A 12 13 CTS_B (V.
Appendix A. Connector Pin Definitions NetVanta 1335 Series Hardware Installation Guide Dial Backup Interface Module Pinouts (DBU Connector) An optional DIM is required for dial backup applications. Table A-12. Analog Modem and ISDN BRI DBU Connector Pinouts Pin Name Description 1-3 — Unused 4 R Network–Ring 5 T Network–Tip 6-8 — Unused Table A-13.