User Manual
Table Of Contents
- Table of Contents
- System Description
- Microwave Path Engineering Basics
- Engineering Guidelines
- Network Turnup Procedure
- User Interface Guide
- 1. Navigating the Terminal Menu
- 2. Menu and System Control
- 3. Menu Descriptions
- > System Status
- > Main Menu
- > System Configuration
- > RF Link Configuration
- > RF Link Performance History (Main Screen)
- > RF Link Error History
- > RF Link Max/Min Received Power History
- > RF Link Min/Max Received Signal Quality History
- > Datapath Provisioning
- > 4xE1 Module Configuration/Status/History (Main Screen)
- > E1x Status/Configuration/Loopback
- > E1x Performance History
- > T1 Module Configuration/Status/History (Main Screen)
- > T1x Status/Configuration/Loopback
- > Ethernet Switch Module Configuration/Status/History (Main Screen)
- > Ethernet Switch Configuration
- > Ethernet Switch Status
- > Management/Utilities (Main Screen)
- > Ping Utility
- > Firmware Upgrade Utility
- > RF Link Management Bridge Configuration
- > System Alarms
- Detail Level Procedures
- MIBs
- Troubleshooting Guide
- 1. Overview
- 2. LED Indicators
- PWR LED
- TST LED
- RF DWN LED
- RF LOW LED
- T1 Interface Alarms
- E1 Interface Alarms
- 1. Display the E1(x) Status screen and check the E1(x) Interface Alarm field to identify the active alarm.
- 1. Verify that the E1 cable is connected to the E1 interface on the TRACER 64x0.
- 2. Verify the connections at the opposite end of the E1 cable.
- 3. Verify that the framing mode (framed, multiframed, or unframed) is the same for both the TRACER 64x0 and the E1 equipment.
- 2. Verify the cable connections for the E1 interface are solid.
- 2. Verify the cable connections for the E1 interface are solid.
- System Alarms
- LAN LEDs
- 3. RF Errors
- 4. Step-by-Step Troubleshooting
- 5. Installing/Troubleshooting the TRACER Hardware
TRACER 6000 Series Integrated System Manual Section 7 MIBs
612806420L1-1E Copyright © 2005 ADTRAN, Inc. 121
adTRACER6000remoteFanStatus
adTRACERremoteFan1* DisplayString RO
adTRACERremoteFan1AlarmTripped* DisplayString RO
adTRACERremoteFan2* DisplayString RO
adTRACERFan2AlarmTripped* DisplayString RO
adTRACERremoteTemperature* DisplayString RO
adTRACERremoteTemperatureTripped* DisplayString RO
adTRACERremoteTransmitter* DisplayString RO
adTRACERremoteClearFanAlarms* Integer RW
adTRACER6000remoteTrapIP
adTRACERremoteTrapIpHost1 IpAddress RW
adTRACERremoteTrapIpHost2 IpAddress RW
adTRACERremoteTrapIpHost3 IpAddress RW
adTRACERremoteTrapIpHost4 IpAddress RW
adTRACERremoteTrapIpHost5 IpAddress RW
adTRACERremotecsu1IntervalTable
adTRACERremotecsu1IntervalEntry
AdTRACERremotecsu1IntervalEntry
adTRACERremotecsu1IntervalIndex Integer RO
adTRACERremotecsu1IntervalNumber Integer RO
adTRACERremoteintervalCSU1Aes Integer RO
adTRACERremoteintervalCSU1Ases Integer RO
adTRACERremoteintervalCSU1Bes Integer RO
adTRACERremoteintervalCSU1Bses Integer RO
adTRACERremoteintervalCSU1Ces Integer RO
adTRACERremoteintervalCSU1Cses Integer RO
adTRACERremoteintervalCSU1Des Integer RO
adTRACERremoteintervalCSU1Dses Integer RO
adTRACERremoteIntervalValidData TruthValue RO
adTRACERremotecsu2IntervalTable
adTRACERremotecsu2IntervalEntry
AdTRACERremotecsu2IntervalEntry
adTRACERremotecsu2IntervalIndex Integer RO
adTRACERremotecsu2IntervalNumber Integer RO
adTRACERremoteintervalCSU2Aes Integer RO
adTRACERremoteintervalCSU2Ases Integer RO
adTRACERremoteintervalCSU2Bes Integer RO
adTRACERremoteintervalCSU2Bses Integer RO
adTRACERremoteintervalCSU2Ces Integer RO
Table 6. MIB Variables for TRACER6000.mib (Continued)
* Listed variable only applies to TRACER high power systems.