User Manual
Table Of Contents
- Table of Contents
- System Description
- Microwave Path Engineering Basics
- Engineering Guidelines
- Network Turnup Procedure
- User Interface Guide
- 1. Navigating the Terminal Menu
- 2. Menu and System Control
- 3. Menu Descriptions
- > System Status
- > Main Menu
- > System Configuration
- > RF Link Configuration
- > RF Link Performance History (Main Screen)
- > RF Link Error History
- > RF Link Max/Min Received Power History
- > RF Link Min/Max Received Signal Quality History
- > Datapath Provisioning
- > 4xE1 Module Configuration/Status/History (Main Screen)
- > E1x Status/Configuration/Loopback
- > E1x Performance History
- > T1 Module Configuration/Status/History (Main Screen)
- > T1x Status/Configuration/Loopback
- > Ethernet Switch Module Configuration/Status/History (Main Screen)
- > Ethernet Switch Configuration
- > Ethernet Switch Status
- > Management/Utilities (Main Screen)
- > Ping Utility
- > Firmware Upgrade Utility
- > RF Link Management Bridge Configuration
- > System Alarms
- Detail Level Procedures
- MIBs
- Troubleshooting Guide
- 1. Overview
- 2. LED Indicators
- PWR LED
- TST LED
- RF DWN LED
- RF LOW LED
- T1 Interface Alarms
- E1 Interface Alarms
- 1. Display the E1(x) Status screen and check the E1(x) Interface Alarm field to identify the active alarm.
- 1. Verify that the E1 cable is connected to the E1 interface on the TRACER 64x0.
- 2. Verify the connections at the opposite end of the E1 cable.
- 3. Verify that the framing mode (framed, multiframed, or unframed) is the same for both the TRACER 64x0 and the E1 equipment.
- 2. Verify the cable connections for the E1 interface are solid.
- 2. Verify the cable connections for the E1 interface are solid.
- System Alarms
- LAN LEDs
- 3. RF Errors
- 4. Step-by-Step Troubleshooting
- 5. Installing/Troubleshooting the TRACER Hardware
TRACER 6000 Series Integrated System Manual Section 7 MIBs
612806420L1-1E Copyright © 2005 ADTRAN, Inc. 115
adDS1CurrentArm Integer RW
adDS1TotalArm Integer RW
adDS1FarCurrentArm Integer RW
adDS1FarTotalArm Integer RW
adDS1CurrentThreshold
adDS1CurrentThrsES Integer RW
adDS1CurrentThrsSES Integer RW
adDS1CurrentThrsSEFS Integer RW
adDS1CurrentThrsUAS Integer RW
adDS1CurrentThrsCSS Integer RW
adDS1CurrentThrsPCVsf Integer RW
adDS1CurrentThrsPCVesf Integer RW
adDS1CurrentThrsLES Integer RW
adDS1CurrentThrsLCV Integer RW
adDS1TotalThreshold
adDS1TotalThrsES Integer RW
adDS1TotalThrsSES Integer RW
adDS1TotalThrsSEFS Integer RW
adDS1TotalThrsUAS Integer RW
adDS1TotalThrsCSS Integer RW
adDS1TotalThrsPCVsf Integer RW
adDS1TotalThrsPCVesf Integer RW
adDS1TotalThrsLES Integer RW
adDS1TotalThrsLCV Integer RW
Table 6. MIB Variables for TRACER6000.mib
adTRACER6000mg
adTRACER6000status
adTRACERRFlinkState DisplayString RO
adTRACERRFClinkState* DisplayString RO
adTRACERrfLow DisplayString RO
adTRACERRXquality DisplayString RO
adTRACERRXLevel DisplayString RO
adTRACERFrequencyPlan DisplayString RO
adTRACERLEDStatus DisplayString RO
adTRACERSlot1 DisplayString RO
adTRACERSlot2 DisplayString RO
Table 5. MIB Variables for ads1.mi2 (Continued)
* Not supported in TRACER 64x0 models. Listed variable only applies to TRACER split systems.