User's Manual
Table Of Contents
- Table of Contents
- System Description
- Microwave Path Engineering Basics
- Engineering Guidelines
- Network Turnup Procedure
- User Interface Guide
- 1. Navigating the Terminal Menu
- 2. Menu and System Control
- 3. Menu Descriptions
- > System Status
- > Main Menu
- > System Configuration
- > RF Link Configuration
- > RF Link Performance History (Main Screen)
- > RF Link Error History
- > RF Link Max/Min Received Power History
- > RF Link Min/Max Received Signal Quality History
- > Datapath Provisioning
- > 4xE1 Module Configuration/Status/History (Main Screen)
- > E1x Status/Configuration/Loopback
- > E1x Performance History
- > T1 Module Configuration/Status/History (Main Screen)
- > T1x Status/Configuration/Loopback
- > Ethernet Switch Module Configuration/Status/History (Main Screen)
- > Ethernet Switch Configuration
- > Ethernet Switch Status
- > Management/Utilities (Main Screen)
- > Ping Utility
- > Firmware Upgrade Utility
- > RF Link Management Bridge Configuration
- > System Alarms
- Detail Level Procedures
- MIBs
- Troubleshooting Guide
- 1. Overview
- 2. LED Indicators
- PWR LED
- TST LED
- RF DWN LED
- RF LOW LED
- T1 Interface Alarms
- E1 Interface Alarms
- 1. Display the E1(x) Status screen and check the E1(x) Interface Alarm field to identify the active alarm.
- 1. Verify that the E1 cable is connected to the E1 interface on the TRACER 64x0.
- 2. Verify the connections at the opposite end of the E1 cable.
- 3. Verify that the framing mode (framed, multiframed, or unframed) is the same for both the TRACER 64x0 and the E1 equipment.
- 2. Verify the cable connections for the E1 interface are solid.
- 2. Verify the cable connections for the E1 interface are solid.
- LAN LEDs
- 3. RF Errors
- 4. Step-by-Step Troubleshooting
- 5. Installing/Troubleshooting the TRACER Hardware
TRACER 6000 Series Integrated System Manual Section 1 System Description
612806420L1-1D Copyright © 2005 ADTRAN, Inc. 13
• Point-to-point transmission, up to 30 miles
• 1U high unit for easy rack mounting
Available Interface Modules
• Quad T1 Module (P/N 1280040L1)
• Quad E1 Module with 120Ω Interface (P/N 1280044L1)
• Quad E1 Module with 75Ω Interface (P/N 1280044L2)
• Quad Ethernet Switch Module (P/N 1280050L1)
E1 Network Module with 120Ω Interface
• Four E1 circuits provided through four RJ-45 connectors
• Complies with CCITT G.703, G.704, and G.823 standards
• E1 circuit alarm reporting capability
• Testing support through local and remote line and link loopbacks
E1 Network Module with 75Ω Interface
• Four E1 circuits provided through a single DB-25, 75Ω connector
• Complies with CCITT G.703, G.704, and G.823 standards (with the BNC breakout panel)
• E1 circuit alarm reporting capability
• Testing support through local and remote line and link loopbacks
•75Ω E1 breakout panel (P/N 1280060L1) provides BNC interfaces for E1 connections
T1 Network Module
• Four T1 circuits provided through four RJ-45 connectors
• Complies with ANSI T1.403 and AT&T 54016 and 62411
• T1 circuit alarm reporting capability
• Testing support through local and remote line and link loopbacks
Quad Ethernet Switch Module
• Four 10/100BaseT/TX interfaces provided through four RJ-45 connectors
• Auto MDI/MDIX crossover on all interfaces
• Back-pressure flow control on all half-duplex interfaces
• Pause-frame flow control on all full-duplex interfaces