User's Manual
Table Of Contents
- Table of Contents
- System Description
- Microwave Path Engineering Basics
- Engineering Guidelines
- Network Turnup Procedure
- User Interface Guide
- 1. Navigating the Terminal Menu
- 2. Menu and System Control
- 3. Menu Descriptions
- > System Status
- > Main Menu
- > System Configuration
- > RF Link Configuration
- > RF Link Performance History (Main Screen)
- > RF Link Error History
- > RF Link Max/Min Received Power History
- > RF Link Min/Max Received Signal Quality History
- > Datapath Provisioning
- > 4xE1 Module Configuration/Status/History (Main Screen)
- > E1x Status/Configuration/Loopback
- > E1x Performance History
- > T1 Module Configuration/Status/History (Main Screen)
- > T1x Status/Configuration/Loopback
- > Ethernet Switch Module Configuration/Status/History (Main Screen)
- > Ethernet Switch Configuration
- > Ethernet Switch Status
- > Management/Utilities (Main Screen)
- > Ping Utility
- > Firmware Upgrade Utility
- > RF Link Management Bridge Configuration
- > System Alarms
- Detail Level Procedures
- MIBs
- Troubleshooting Guide
- 1. Overview
- 2. LED Indicators
- PWR LED
- TST LED
- RF DWN LED
- RF LOW LED
- T1 Interface Alarms
- E1 Interface Alarms
- 1. Display the E1(x) Status screen and check the E1(x) Interface Alarm field to identify the active alarm.
- 1. Verify that the E1 cable is connected to the E1 interface on the TRACER 64x0.
- 2. Verify the connections at the opposite end of the E1 cable.
- 3. Verify that the framing mode (framed, multiframed, or unframed) is the same for both the TRACER 64x0 and the E1 equipment.
- 2. Verify the cable connections for the E1 interface are solid.
- 2. Verify the cable connections for the E1 interface are solid.
- LAN LEDs
- 3. RF Errors
- 4. Step-by-Step Troubleshooting
- 5. Installing/Troubleshooting the TRACER Hardware
TRACER 6000 Series Integrated System Manual Section 7 MIBs
612806420L1-1D Copyright © 2005 ADTRAN, Inc. 115
TRACER6000.mib adTRACERtotalThrsESon the threshold for Total ES has been exceeded.
adTRACERtotalThrsESoff the threshold for Total ES has not been exceeded.
adTRACERtotalThsSESon the threshold for Total SES has been exceeded.
adTRACERtotalThsSESoff the threshold for Total SES has not been exceeded.
adTRACERfan1Alarm* fan 1 currently has an active alarm.
adTRACERfan1Fail* fan 1 has failed.
adTRACERfan1AlarmOff* the fan 1 alarm has turned off after it was activated.
adTRACERfan1On* fan 1 has turned back on after a fan 1 failure.
adTRACERfan2Alarm* fan 2 currently has an active alarm.
adTRACERfan2Fail* fan 2 has failed.
adTRACERfan2AlarmOff* the fan 2 alarm has turned off after it was activated.
adTRACERfan2On* fan 2 has turned back on after a fan 2 failure.
adTRACERtempAlarm* the temperature alarm has turned on due to an
increase in internal temperature.
adTRACERtempAlarmOff* the temperature alarm has turned off due to a
decrease in internal temperature.
adTRACERtxshutdown* the transmitter has shut down due to temperature
constraints.
Table 3. Traps Supported by the TRACER 64x0 (Continued)
MIB Trap This trap indicates that....
* Listed traps only apply to TRACER high power systems.