Preliminary
Char. / Point Type Scan Point Definition Description
1 / 1 Status Frequency Plan 0 = Plan A, 1 = Plan B
1 / 2 Status 10 Second BERT Test 0 = Normal, 1 = In Test
1 / 3 Status Local T1A Line Loopback 0 = Normal, 1 = Loop
1 / 4 Status Local T1B Line Loopback 0 = Normal, 1 = Loop
1 / 5 Status Local T1A Link Loopback 0 = Normal, 1 = Loop
1 / 6 Status Local T1B Link Loopback 0 = Normal, 1 = Loop
1 / 7 Status Remote T1A Link Loopback 0 = Normal, 1 = Loop
1 / 8 Status Remote T1B Link Loopback 0 = Normal, 1 = Loop
2 / 1 Alarm RFC Link Fail 0 = Normal, 1 = Alarm
2 / 2 Alarm Code Sync Fail 0 = Normal, 1 = Alarm
2 / 3 Alarm Carrier Sync Fail 0 = Normal, 1 = Alarm
2 / 4 Alarm T1 Mux Sync Fail (Link Err) 0 = Normal, 1 = Alarm
2 / 5 Alarm Remote RF Link Down 0 = Normal, 1 = Alarm
2 / 6 Alarm RF Low 0 = Normal, 1 = Alarm
2 / 7 Alarm Remote Test Fail 0 = Normal, 1 = Alarm
2 / 8 Unused
3 / 1 Alarm T1A BPV 0 = Normal, 1 = Alarm
3 / 2 Alarm T1A Red Alarm 0 = Normal, 1 = Alarm
3 / 3 Alarm T1A Yellow Alarm 0 = Normal, 1 = Alarm
3 / 4 Alarm T1A AIS (Blue Alarm) 0 = Normal, 1 = Alarm
3 / 5 Alarm T1A Transmit AIS 0 = Normal, 1 = Alarm
3 / 6 Unused
3 / 7 Unused
3 / 8 Unused
4 / 1 Alarm T1B BPV 0 = Normal, 1 = Alarm
4 / 2 Alarm T1B Red Alarm 0 = Normal, 1 = Alarm
4 / 3 Alarm T1B Yellow Alarm 0 = Normal, 1 = Alarm
4 / 4 Alarm T1B AIS (Blue Alarm) 0 = Normal, 1 = Alarm
4 / 5 Alarm T1B Transmit AIS 0 = Normal, 1 = Alarm
4 / 6 Unused
4 / 7 Unused
4 / 8 Unused
Table 3-1. TRACER TBOS Alarm and Status Map