C. RF Status
A graphical indicator of the TRACER RF links is located beneath the Technical Support contact
number. The status of the received radio link is indicated as
RF UP or RF DOWN for each direction.
This RF status display corresponds to the
RF DOWN LED on the front of the unit.
D. T1 Status (Error/Alarm Only)
A visual status of current errors/alarms on the T1 interfaces (for both the local and remote TRACER
systems) is provided on the TRACER 4208 System Status menu page.
T1A through T1H displayed in
reverse highlight indicates an active error or alarm condition. Individual T1 status pages (accessible
from the main menu) provide detailed T1 information.
E. Remote TRACER Status
The right portion of the TRACER 4208 System Status menu page reports the status of the remote
TRACER 4208 (the system across the wireless link from the active terminal). If the RF link is down,
DATA NOT AVAILABLE is displayed in place of the remote system status information.
F. Local TRACER Status
The left portion of the TRACER 4208 System Status menu page reports the status of the local
TRACER 4208 (the system where the active terminal is attached).
G. Si t e Nam e
The SITE NAME field provides a user-defined alphanumeric description (up to 25 characters) for the
TRACER 4208 system. This field is defined from the TRACER 4208 System Configuration menu
page.
H. Frequency Plan
Displays the frequency plan (A or B) for the TRACER 4208 unit. For an operational TRACER 4208
system you should have one A and ond B frequency plan.
I. Rx Power
Displays the approximate receiver levels (for both the local and remote units) using a series of symbols
(
#). The more symbols (#) displayed, the stronger the signal. If the link is down and remote end data is
unavailable,
DATA NOT AVAILABLE is displayed in place of the symbols (#).
J. Tx Power
Displays the approximate transmitter levels (for both the local and remote units) using a series of
symbols (
#). The more symbols (#) displayed, the stronger the signal. If the link is down and remote
end data is unavailable,
DATA NOT AVAILABLE is displayed in place of the symbols (#).
K. Navigation Reminders
Displays system navigation reminders. For more details on system navigation, refer to Navigating the
Terminal Menu on page 42.