User Manual

Table Of Contents
TRACER 4208 System Manual Section 3 Engineering Guidelines
612804208L1-1A © 2003 ADTRAN, Inc. 33
User Interface
Panel Alarm LEDs
Diagnostics Line and Link Loopbacks
Tes t P oin ts RSSI and TX PWR
Alarms Normally Open (NO) and Normally Closed (NC)
VT100 Terminal
Menu Driven User Interface, Control of the
Remote End, Loopback Test, Optional
Password Protection, Event History
VT100 Terminal Interface
Data Rate 9600 bps
Data Bits 8
Parity None
Stop Bits 1
Terminal Emulation VT100
Mechanical and Environmental
Operating Temperature -25° C to 65° C
Size 17.12” W x 10.80” D x 1.72” H
Humidity 95%, Non-condensing
Weight 7 lbs
Power
Input Voltage
21 to 60 VDC, either polarity referenced to
ground
Power Consumption < 18 Watts
Connector 2 pin terminal block (DC)
Fuse 1A, 250V slow-blo fuse (2-inch)
Table 9. At-A-Glance Specifications (Continued)
Hardware Description Specification