User Manual

Table Of Contents
TRACER 4102/4202 System Manual Section 3 Engineering Guidelines
612804202L1-1A © 2004 ADTRAN, Inc. 33
T1 Interface
Capacity 1.544 Mbps (each)
Connection RJ-48C jacks
Line Code B8ZS, AMI
Framing ESF, D4
Alarms AIS, Red, Yellow, BPVs, LOS
Loopbacks Local and remote (line and link)
User Interface
Panel Alarm LEDs
Diagnostics Line and Link Loopbacks
Test Points RSSI and GND
Alarms Normally Open (NO) and Normally Closed (NC)
VT100 Terminal
Menu Driven User Interface, Control of the Remote End,
Loopback Test, Optional Password Protection, Event
History
VT100 Terminal Interface
Data Rate 9600 bps
Data Bits 8
Parity None
Stop Bits 1
Terminal Emulation VT100
Mechanical and Environmental
Operating Temperature -25° C to 65° C
Size 17.12” W x 9.34” D x 1.72” H
Humidity 95%, Non-condensing
Weight
9 lbs (TRACER 4102), 7 lbs (TRACER 4202)
Power
Input Voltage 21 to 60 VDC, either polarity referenced to ground
Power Consumption < 20 Watts
Connector 2 pin terminal block (DC)
Fuse 1A, 250V slow-blo fuse (2-inch)
Table 9. At-A-Glance Specifications (Continued)
Hardware Description Specification