User guide

Ethernet RFC 2544 Test
84 AXS-200/805/855
Frame Loss Configuration
The accepted values are as follows:
`
³ Verdict Threshold (%): Set the threshold value in percentage of frame
loss. If the determined frame loss value is lower or equal to the
threshold value, the test is declared as PASS. If the determined frame
loss value for a specific frame size is greater than the threshold value,
the test is declared as FAIL. This value should range from 0.1 % to
100 % and applies to all the 7 RFC 2544 frame sizes or for the 7
user-defined frame sizes.
Note: When the Dual Test Set parameter is set to Local in Global Configuration
on page 70, the Maximum Rate and Verdict Threshold are configured
independently for each direction: Local-to-Remote and Remote-to-Local.
Note: Verdict Threshold parameter will be
editable only when the RFC 2544
Pass/Fail Verdict parameter is
Enabled in Global Configuration on
page 70.
Interface Maximum Rate
Speed % Mbps
10 Mbps 0.1 - 100,
default = 100
0.01 - 10, default = 10
100 Mbps 0.1 - 100, default = 100
1000 Mbps 1 - 1000, default = 1000