Ethernet Test Setup
Multi Protocol Test Set 59
Remote Selection
³ Scan Subnet: When scan subnet is
enabled, the local module scans
the subnet to discover remote
modules. The scan relies on the
subnet mask information
configured through the Network
tab (see Network on page 49).
³ Remote Capability: Select the
Remote Capability. Choices are
Remote Loopback and DTS RFC 2544. The default setting is Remote
Loopback.
If Remote Loopback is selected, it will discover the module supporting
the Remote Loopback feature.
If DTS RFC 2544 is selected, it will discover the module supporting the
DTS RFC 2544 feature.
To put the remote module into Smart Loopback or DTS RFC 2544
mode:
1. Once the list of discovered units is displayed, press the down arrow to
highlight the list box (the box will be outlined in blue).
2. Press the button to select the list (the box will be outlined in
yellow).
3. Use the navigation arrows to highlight the target module.
4. If Remote Capability is set to Remote Loopback, select the Loop Up
button to enable the Smart Loopback mode on the target module.
If Remote Capability is set to DTS RFC 2544, select the Connect
button to establish the connection with the target module.
An icon will be displayed in the title bar if the Loop Up or the Connect
operation is successful.