User guide

DS3 Test
252 AXS-200/805/855
DS3 Loopbacks
DS3 Loopbacks
Loopbacks are not available with Monitor test mode.
Press , select DSn/PDH, DS3, and Loopbacks.
³ Receive: The value displayed, FF
None (All Ones), should be the
value selected in Transmit on
remote unit.
³ Transmit: Select the transmit
loopback code. Choices are FF
None (All Ones), 32 DS3 EQPT
FAIL (SA), 1C DS3 LOS, 00 DS3
Out-Of-Frame, 2C DS3 AIS
Received, 34 DS3 IDLE
Received, 1E DS3 EQPT FAIL (NSA), 3A Common EQPT FAIL, 2A
Multiple DS1 LOS, 0A DS1 EQPT FAIL (SA), 3C Single DS1 LOS, and
06 DS1 EQPT FAIL (NSA). The default setting is FF None (All Ones).
³ DS3 FEAC: is available when Term mode (Term-DSX or Ter m DSX-HI)
and C-bit framing are selected from the setup page. Select the DS3
FEAC code. Choices are None, LINE, NIU, COT, COT-alt2, Repeater,
and RT-alt. The default setting is None.
³ DS1 FEAC: is available when Term mode (Term-DSX or Ter m DSX-HI)
and C-bit framing are selected from the setup page. Select the DS1
FEAC code. Choices are None, ALL, and 1 to 28. The default setting is
None.
³ Local: Select the local loopback type. Choices are None, Self-Loop,
and Local-NW. The default setting is None.
Self-Loop loops the transmitter (TX) of the AXS-200/805/855 to its
receiver (RX).
Local-NW: loops the receiver (RX) of the AXS-200/805/855 to the
transmitter (TX), manual DS1 loopback towards the network.