User guide
E1-A and E1-B Tests
Multi Protocol Test Set 239
Facility Results
³ Signal, Slips, and RTD
Allows to either displays the signal, slips, or Round Trip Delay (RTD)
status.
³ Signal status displays the received signal frequency (Hz) and it
level (dBm and Vpp). If no signal is received, NO SIGNAL is
displayed.
³ Slips displays the received clock slips. A reference clock must be
connected on the E1-B RX port. Slips compare the E1-A clock to
the reference E1-B clock and displays the slips count (Slips) and
difference in frequency deviation in Hz (Dev). If no signal clock is
received, NO REFERENCE is displayed.
³ RTD displays the measured round trip delay in ms. RTD is not
available with Monitor 75 (ohm), Monitor 120 (ohm), and
Bridged test modes.
³ Report: Select the Report button to generate a report for the test. Refer
to Report Generation on page 91 to generate and save a report file.