User guide
Ethernet BERT Test
Multi Protocol Test Set 119
Summary Results
³ BER Threshold: Enter the threshold amount as follows (if the bit error
results exceed this value, the test will be declared as failed):
³ If the Pass/Fail Verdict is Bit Error Count, the accepted threshold
range is 6 digits with a default value of 0.
³ If the Pass/Fail Verdict is Bit Error Rate, the accepted threshold
range is 1.0E-14 to 1.0E0 with a default value of 1.0E-2.
³ The Pass/Fail Verdict is displayed on the screen with the help of
the following symbols:
= PASS
= FAIL
³ Reset: Press this button at any time to clear the results and statistics.
This does not interrupt the monitoring process nor cause errors on the
transmitted stream while a test is running. Use after an injection of bit
errors to clear results.
³ Bit Error Count: Displays the sum of mismatch ‘0’ and mismatch ‘1’
errors.
³ Bit Error Rate: Displays the bit error rate with a range of 1.0E-14 to
1.0E0.
³ Report: Select the Report button to generate the report file of the
results and statistics. Refer to Report Generation on page 91 to
generate and save a report file.