User guide

Ethernet BERT Test
118 AXS-200/805/855
Summary Results
³ Start Time: The time when the BERT test was started.
³ Duration: The length of time from when the test was started, until
when the test was completed.
³ RX Rate: Display the receive rate in terms of a percentage of the line
rate or Mbps.
³ TX Rate: Set the transmission rate in terms of a percentage of the line
rate or in Mbps.
The accepted range and increments are as follows:
³ Longest SDT (ms): Displays the longest service disruption time
measured from the beginning of the test.
³ Bit Error Amount: Set the bit error amount to inject into traffic. The
accepted range is from 1 to 50 with a default value of 1. This
parameter is configurable at any time whether or not a test is running.
³ Inject: Select this button to inject bit errors on the transmitted traffic.
Bit errors are injected only while a test is running.
Interface Maximum Rate
% Mbps
10 Mbps 0.001 - 100.000,
default = 100.000
0.001 - 10.000, default = 10.000
100 Mbps 0.001 - 100.000, default = 100.000
1000 Mbps 0.001 - 1000.000, default = 1000.000