User guide

Ethernet BERT Test
Multi Protocol Test Set 109
Global Configuration
Global Configuration
The rate and frame size can be changed dynamically while the test is
running. The Pass/Fail verdict can be set at anytime independent of
whether a test is started.
Press , select ETHERNET, BERT, Configuration, and the Global tab.
Note: Service Disruption Time feature is always active.
³ Framing: Select Ethernet,
Ethernet/IPv4/UDP or
Ethernet/IPv6/UDP. The default
value is Ethernet.
³ Rate Unit: Select the unit for the
transmission and receive rate.
Choices are Mbps and %. The
default setting is Mbps.
³ TX Rate: Set the transmission rate
in terms of a percentage of the line rate or in Mbps.
The accepted range and increments are as follows:
Interface Maximum Rate
% Mbps
10 Mbps 0.1 - 100,
default = 100
0.01 - 10, default = 10
100 Mbps 0.1 - 100, default = 100
1000 Mbps 1 - 1000, default = 1000