User guide
Ethernet RFC 2544 Test
Multi Protocol Test Set 97
Back-to-Back Results
³ Layer: Select the layer for determining the back-to-back results layer to
display. Choices are All, Ethernet and IP. The default setting is All.
³ All: Considers all layers to display the Back-to-Back Results and
represents the Ethernet line utilization.
³ Ethernet: Displays the Back-to-Back Results calculated at the
Ethernet layer.
³ IP: Displays the Back-to-Back Results calculated at the IP layer.
The back-to-back results displayed on the bottom half of the page are
displayed for the selected frame size distribution.
Note: When the Dual Test Set parameter is set to Local in Global Configuration
on page 70, the Back-to-Back subtest results are presented independently
for each direction: Local-to-Remote and Remote-to-Local.
Note: For DTS RFC 2544, the results for the
Local-to-Remote direction are
obtained between test iterations.
Note: The Pass/Fail verdict is displayed for
each frame size. To set the Pass/Fail
verdict, refer to the RFC 2544 Global
Configuration tab. See Pass/Fail
Verdict on page 72.
= PASS
= FAIL