Specifications
SCU Control Port Operation
61181310L2-5D 19
Table 6. Provisioning Menu Options
Menu Item Description Default
DSX-1 Line
Buildout
Conditions the output signal to provide a 0 dB
output level to the DSX. Options range from 0
to 655 feet in 133-foot increments.
0 to 133 feet
Line Coding AMI or B8ZS B8ZS
Line Framing SF, ESF, or unframed ESF
Loopback Timeout 20 minutes, 60 minutes,
120 minutes, or disabled
120 minutes
DS1 TX Level Conditions output signal buildout at:
0 dB, –7.5 dB, –15 dB, or –22.5 dB
0 dB
Network Source
1
Selects DSX or multiplexer input/output
interface:
DSX/DS1
MUX A
MUX B
Auto MUX
DSX/DS1
Service State
2
Selects one of three service states:
In Service
Out-of-Service, Unassigned
Out-of-Service, Maintenance
Out-of-Service, Unassigned
Span Power Disabled, –130 volts, ±130 volts –130 volts
External Alarms Disabled, Enabled Disabled
Card Configuration T1–OR, T1–NIU. Changes to this option can be
seen on the Status screen.
T1-OR
AIS Disabled, Enabled Disabled
1. For Network Source settings, the following options apply:
• DSX/DS1: The module will use the DSX-1 interface for the network source when the module is provisioned
for the T1-OR mode. If the module is provisioned for the T1-NIU mode, the network source will be the DS1
interface. The MUXes will not be used, even if present.
• MUX A: The module will use MUX A as its data source. The module will not switch to MUX B in the case of
a MUX A failure. The EQ jacks can be used as a temporary test point in conjunction with the EQ jack setting
on the loopback/test screen.
• MUX B: The module will use MUX B as its data source. The module will not switch to MUX A in the case of
a MUX B failure. The EQ jacks can be used as a temporary test point in conjunction with the EQ jack setting
on the loopback/test screen.
• Auto MUX: The module will default to MUX A as its data source. In the event of a MUX A failure, the module
will perform a protection switch to MUX B if it is present and in service. The EQ jacks can be used as a
temporary test point in conjunction with the EQ jack setting on the loopback/test screen.
2. The default service state is Out-of-Service Unassigned
• Out-of-Service Unassigned allows the loops to train up but does not connect to the DSX or MUX interface.
• The Out-of-Service Maintenance setting allows active connections to the DSX or MUX interface; however, no
alarms will be generated.
• The In Service setting allows full functioning connections to DSX or MUX interfaces.