Operation Manual
61180019L1-5A Issue 1, May 2004 3
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user’s authority to operate this
equipment.
2. INSTALLATION
After unpacking the Total Access 1500 19-Inch
Chassis, inspect it for damage. If damage has occurred,
file a claim with the carrier, then contact ADTRAN
Customer Service. Refer to the Warranty and Customer
Service section for further information. If possible, keep
the original shipping container for returning the 19-Inch
Chassis for repair or for verification of shipping
damage.
NOTE
This product is intended for installation in
restricted access locations only.
CAUTION
Electronic modules can be damaged by ESD.
When handling modules, wear an antistatic
discharge wrist strap to prevent damage to
electronic components. Place modules in
antistatic packing material when transporting
or storing. When working on modules, always
place them on an approved antistatic mat that is
electrically grounded.
WARNING
To prevent electrical shock, do not install
equipment in a wet location or during a
lightning storm.
Tools Required
The required tools for the Total Access 1500 19-Inch
Chassis installation are as follows:
• Wire-wrap tool
• #2 phillips-head screwdriver
• #1 phillips-head screwdriver
• Straight-slot-head screwdriver
• Multimeter
• Crimping tool for power lugs
• Wire strippers
• Side cutters
• 3/16-inch wrench
Material that should be on hand includes the following:
• Four screws for mounting each Total Access 1500
19-Inch Chassis to the rack
• Shielded 2-wire, twisted pair cross-connect wire
with drain, such as AT&T P7 wire
• Insulated wire for power connections
• Insulated wire for frame ground
• Lugs for the power wire and Frame Ground
connection
Unpack and Inspect the Chassis
Each Total Access 1500 19-Inch Chassis is shipped in
its own cardboard shipping carton unless it was ordered
as a fully racked cabinet or wall mount system. Open
each carton carefully and avoid cutting too deep into the
carton with sharp objects.
Mounting the Chassis
The Total Access 1500 19-Inch Chassis can be flush-
mounted or mid-mounted.
Mounting Bracket Orientation
The Total Access 1500 19-Inch Chassis comes with
mounting brackets that can be mounted with the flanges
facing forward or backward in two different locations
on the chassis sides. This allows the chassis to be flush-
mounted or mid-mounted. Attaching the mounting
brackets to the chassis requires three screws on each
side that are supplied with the unit.
The mounting brackets can be used for 19 or 23-inch
rack applications:
• The narrow side should be screwed to the chassis
for a 23-inch rack.
• The wide side should be screwed to the chassis for
a 19-inch rack
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.