B-6 61179605L5-5B
SCA FILE EXAMPLE
Figure B-1 provides an example of an SCA file.
17 Performance Primitive
Notifications
bit 7 = segment anomaly
bit 6 = CRC anomaly
bit 5 = segment defect
bit 4 = loss of sync word defect
bit 3 = SNR margin defect
bit 2 = loop attenuation defect
bit 1 = loss of sync word failure
bit 0 = tip/ring reversal
18 SHDSL ES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
19 SHDSL SES 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
1A SHDSL UAS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
1B SHDSL CVC 15 Minute Alarm
Threshold
0 = Disabled
1 to 65535 = threshold in seconds
1C SHDSL LOSWS 15 Minute
Alarm Threshold
0 = Disabled
1 to 900 = threshold in seconds
1D Line Rate Control 0 = STU-C
1 = STU-R
1E SHDSL OS 15 Minute Alarm
Threshold
0 = Disabled
1 to 900 = threshold in seconds
1F Outage Auto-Retrain 0 = Disabled
1 = Enabled
20 - 27 Reserved Options for future use
Table B-5. LocSTULineProvisioning (Continued)
Column Option Values