Section 5, User Interface - Menu Descriptions
61179605L5-5B 5-69
Card Provisioning Menu
The Card Provisioning menu (see Figure 5-49) is used to set the service state of the main
circuit board card. The default value for the Card Service State is Out of Service-Maintenance.
Changes to this service state are reflected on all 24 ports.
Figure 5-49. Card Provisioning Menu
The Card Provisioning menu options are shown in Table 5-50.
Table 5-50. Card Provisioning Menu Options
Option Description Function
1 Service State This option is used to select the card service state. The
available service states are as follows:
• In Service – The SHDSL services are available, if
installed, and Link Down and Threshold alarms are
reported.
• Out of Service-Unassigned – No SHDSL services are
available. No Link Down and Threshold alarms are
reported.
• Out of Service-Maintenance – SHDSL services are
available. No Link Down and Threshold alarms are
reported.
2 Restore Factory Defaults This option displays the “Restore Factory Defaults
Screen” on page 5-70.
09/01/05 03:58
Total Access 1240
Card Provisioning
1. Service State = OOS-Maintenance
2. Restore Factory Defaults
Selection:
'?' - System Help