Specifications

Serial Interface Configuration Command Set Command Reference Guide
366 © 2003 ADTRAN, Inc. 61950860L1-35D
serial-mode <mode>
Use the serial-mode command to specify the electrical mode for the interface. Use the no form of this
command to return to the default value.
Syntax Description
<mode>
Specifies the electrical specifications for the interface
V35
Configures the interface for use with the V.35 adapter cable (P/N 1200873L1)
X21
Configures the interface for use with the X.21 adapter cable (P/N 1200874L1)
Default Values
<mode> V35
Command Modes
(config-ser 1/1)# Serial Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Functional Notes
The pinouts for each of the available interfaces may be found in the Hardware Configuration Guide located on
the
NetVanta 3000 Series System Manual
CD (provided in shipment).
Usage Examples
The following example configures the serial interface to work with the X.21 adapter cable:
(config)#
interface serial 1/1
(config-ser 1/1)#
serial-mode X21