NetVanta 4305 Hardware Installation Guide 1200890L1 NetVanta 4305 Chassis 1200861L1 NetVanta 56K/64K Network Interface Module 1200862L1 NetVanta T1/FT1 Network Interface Module 1200863L1 NetVanta T1/FT1+DSX-1 Network Interface Module 1200866L1 NetVanta Serial Network Interface Module 1200868L1 NetVanta E1/FE1 Network Interface Module 1200872L1 NetVanta Dual T1 Network Interface Module 1200864L1 NetVanta Analog Modem Dial Backup Interface Module 1200865L1 NetVanta ISDN BRI Dial Backup Interf
Trademarks NetVanta 4305 Hardware Installation Guide Trademarks Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.
NetVanta 4305 Hardware Installation Guide Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption. Warnings provide information that could prevent damage to the equipment or endangerment to human life. 61200890L1-34B © 2004 ADTRAN, Inc.
Safety Instructions NetVanta 4305 Hardware Installation Guide Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. 2. Avoid using a telephone (other than a cordless-type) during an electrical storm. There is a remote risk of shock from lightning. 3.
NetVanta 4305 Hardware Installation Guide FCC-Required Information FCC-Required Information FCC regulations require that the following information be provided in this manual: 1. This equipment complies with Part 68 of FCC rules and requirements adopted by ACTA. Each registered interface has a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, provide this information to the telephone company. 2.
FCC Radio Frequency Interference Statement NetVanta 4305 Hardware Installation Guide FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
NetVanta 4305 Hardware Installation Guide Industry Canada Compliance Information Industry Canada Compliance Information Notice: The Industry Canada label applied to the product (identified by the Industry Canada logo or the “IC:” in front of the certification/registration number) signifies that the Industry Canada technical specifications were met. Notice: The Ringer Equivalence Number (REN) for this terminal equipment is supplied in the documentation or on the product labeling/markings.
Affidavits NetVanta 4305 Hardware Installation Guide Affidavits Affidavit Requirements for Connection to Digital Services • An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voiceband analog signals and transmitted on the network.
NetVanta 4305 Hardware Installation Guide Affidavits Affidavit for Connection Of Customer Premises Equipment to 1.
Warranty and Customer Service NetVanta 4305 Hardware Installation Guide Warranty and Customer Service ADTRAN will repair and return this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at: http://support.adtran.com (Click on Warranty and Repair Information, under Support.) Product Registration Registering your product helps ensure complete customer satisfaction.
NetVanta 4305 Hardware Installation Guide Product Support Information Pre-Sales Inquiries and Applications Support Your reseller should serve as the first point of contact for support. If additional pre-sales support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, latest product documentation, application briefs, case studies, and a link to submit a question to an Applications Engineer.
Product Support Information NetVanta 4305 Hardware Installation Guide Training The Enterprise Network (EN) Technical Training Department offers training on our most popular products. These courses include overviews on product features and functions while covering applications of ADTRAN's product lines. ADTRAN provides a variety of training options, including customized training and courses taught at our facilities or at your site.
Table of Contents Introduction to the NetVanta 4305 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unpack and Inspect the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contents of ADTRAN Shipments . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents 14 NetVanta 4305 Hardware Installation Guide © 2004 ADTRAN, Inc.
List of Figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. NetVanta 4305 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 4305 Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetVanta 56K/64K NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Figures 16 NetVanta 4305 Hardware Installation Guide © 2004 ADTRAN, Inc.
List of Tables Table 1. Table A-1. Table A-2. Table A-3. Table A-4. Table A-5. Table A-6. Table A-7. Table A-8. Table A-9. Table A-10. 61200890L1-34B NetVanta 4305 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10/100BaseT Ethernet Port Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Console Port (DCE) Pinout for NetVanta 4305 (p/n 1200890L1) . . . . . . . . . . . . . . . . . . . .
List of Tables 18 NetVanta 4305 Hardware Installation Guide © 2004 ADTRAN, Inc.
1. INTRODUCTION TO THE NETVANTA 4305 The NetVanta 4305 is a mid-range IP router designed for medium-to-large office connectivity over Frame Relay or point-to-point (PPP) networks. This modular platform offers a complete solution for access routing and WAN connectivity in a single, compact package. The main base unit supports a variety of interchangeable network interface modules (NIMs) and dial backup interface modules (DIMs).
Introduction to the NetVanta 4305 NetVanta 4305 Hardware Installation Guide • Integrated EIA-232 DCE configuration port (DB-9) • Optional dial backup (ISDN BRI DIM, ISDN S/T DIM, or analog modem) • Optional VPN Accelerator Card provides encryption/decryption and security acceleration services • Front panel LEDs • Dimensions: 17.22”W x 1.72”H x 10.
NetVanta 4305 Hardware Installation Guide Introduction to the NetVanta 4305 NetVanta T1/FT1+ DSX-1 NIM (1200863L1) Shipments of the T1/FT1 + DSX-1 NIM include the following items: • • • T1/FT1 + DSX-1 Network Interface Module Quick Start Guide 15-foot RJ-45 to RJ-45 cable (ADTRAN P/N 3125M008@A) NetVanta E1/FE1 NIM (1200868L1) Shipments of the E1/FE1 NIM include the following items: • • • E1/FE1 Network Interface Module Quick Start Guide 15-foot RJ-45 to RJ-45 cable (ADTRAN P/N 3125M008@A) NetVanta
Introduction to the NetVanta 4305 • NetVanta 4305 Hardware Installation Guide RJ-45 to RJ-11 cable (ADTRAN P/N 3125M007@A) NetVanta ISDN S/T DIM (1200875L1) Shipments of the ISDN S/T DIM include the following items: • • • ISDN S/T Dial Backup Interface Module Quick Start Guide RJ-45 to RJ-11 cable (ADTRAN P/N 3125M007@A) NetVanta VPN Accelerator Card (1202368L1) Shipments of the VPN Accelerator Card include the following items: • • VPN Accelerator Card Quick Start Guide Option modules are intended
NetVanta 4305 Hardware Installation Guide 2. Physical Description PHYSICAL DESCRIPTION Reviewing the Base Unit Front Panel Design Figure 1 shows the NetVanta 4305 front panel. STATUS NET 1 WAN DBU TD RD NET 2 WAN DBU TD RD LAN 1 TD RD LNK LAN 2 TD RD LNK WIDE SLOT 1 STATUS ACTIVITY TEST NetVanta 4305 Figure 1. NetVanta 4305 Front Panel Layout Front Panel LEDs Table describes the front panel LEDs. Table 1.
Physical Description NetVanta 4305 Hardware Installation Guide Table 1. NetVanta 4305 LEDs (Continued) For these LEDs… LAN 1/ LAN 2 LNK WIDE SLOT 1 STATUS WIDE SLOT 1 ACTIVITY WIDE SLOT 1 TEST 24 This activity… Indicates that… Green (solid) The 10BaseT Ethernet link is up. Yellow (solid) The 100BaseT Ethernet link is up. Off The card is not installed. Green (solid) The card is recognized by the system. Red (solid) Alarm condition with card.
NetVanta 4305 Hardware Installation Guide Physical Description Reviewing the Rear Panel Design Figure 2 shows the rear panel for the NetVanta 4305. The chassis is shown with the T1/FT1+DSX-1 NIM installed. ETH 0/2 WAN-T1 WAN-T1 DSX-1 DSX-1 DBU DBU WAN-T1 DSX-1 DBU 100-250VAC 50/60Hz CONSOLE SLOT 3 WIDE MODULE SLOT 2 NET/DBU SLOT 1 NET/DBU ETH 0/1 Figure 2.
Option Modules 3. NetVanta 4305 Hardware Installation Guide OPTION MODULES The NetVanta 4305 accepts several option modules designed to meet a variety of networking requirements. The option modules are of three types: plug-in Network Interface Modules (NIMs), plug-on Dial Backup Interface Modules (DIMs), and Wide NIMs. NIMs are cards which plug directly into the option module slot (labeled SLOT 1 NET/DBU or SLOT 2 NET/DBU), located on the rear of the base unit.
NetVanta 4305 Hardware Installation Guide Option Modules Network Interface Modules NetVanta 56K/64K NIM (P/N 1200861L1) The 56K/64K NIM (shown in Figure 3) provides a WAN-DDS interface for the NetVanta 4305. Refer to Table A-3 on page 46 for the WAN-DDS connector pinout, and refer to Table A-9 on page 49 for the DBU connector pinout. An optional DIM is required for dial backup applications. Figure 3.
Option Modules NetVanta 4305 Hardware Installation Guide NetVanta T1/FT1 NIM (P/N 1200862L1 or P/N 1202862L1) The T1/FT1 NIM (shown in Figure 4) provides a T1 (full T1 or fractional T1) WAN interface for the NetVanta 4305. Refer to Table A-4 on page 46 for the WAN-T1 connector pinout, and refer to Table A-9 on page 49 for the DBU connector pinout. An optional DIM is required for dial backup applications. WAN-T1 DBU Figure 4.
NetVanta 4305 Hardware Installation Guide Option Modules NetVanta T1/FT1+DSX-1 NIM (P/N 1200863L1 or P/N 1202863L1) The T1/FT1 + DSX-1 NIM (see Figure 5) provides a full T1 or fractional T1 network interface and a DSX1 interface. Refer to Table A-4 on page 46 for the WAN-T1 connector pinout, Table A-6 on page 47 for the DSX-1 connector pinout, and Table A-9 on page 49 for the DBU connector pinout. An optional DIM is required for dial backup applications. WAN-T1 DSX-1 DBU Figure 5.
Option Modules NetVanta 4305 Hardware Installation Guide NetVanta Dual T1 NIM (P/N 1200872L1) The NetVanta Dual T1 NIM (see Figure 6) provides two WAN T1 interfaces for the NetVanta 4305. The module provides up to 2.048 Mbps on each network interface. Refer to Table A-5 on page 46 for the pinouts. Refer to Table A-10 on page 49 for the DBU connector pinout. An optional DIM is required for dial backup applications. Figure 6.
NetVanta 4305 Hardware Installation Guide Option Modules NetVanta Serial NIM (P/N 1200866L1) The NetVanta Serial NIM (shown in Figure 7) is user-configurable to be either a V.35 or X.21 (V.11) interface. This module supports rates up to a maximum of 10 Mbps. An additional V.35 (ADTRAN P/N 1200873L1) or X.21 (ADTRAN P/N 1200874L1) cable is required (see Caution, below). Refer to Table A-8 on page 48 for the Serial connector pinout, and refer to Table A-10 on page 49 for the DBU connector pinout.
Option Modules NetVanta 4305 Hardware Installation Guide NetVanta E1/FE1 NIM (P/N 1200868L1) The NetVanta E1 NIM (see Figure 8) provides a WAN-E1 interface for the NetVanta 4305 meeting the requirements of ITU-T G.703/G.704. The module provides a single 2.048 Mbps network interface. Refer to Table A-5 on page 46 for the pinouts. Refer to Table A-10 on page 49 for the DBU connector pinout. An optional DIM is required for dial backup applications. WAN-E1 DBU Figure 8.
NetVanta 4305 Hardware Installation Guide Option Modules NetVanta E1/FE1 with G.703 Drop NIM (P/N 1200878L1) The NetVanta E1/FE1 with G.703 Drop NIM (see Figure 9) provides a single WAN-E1 interface (2.043 Mbps) with user-selectable TS0 assignment and a G.703 drop port which may be used to drop and insert traffic to an E1 PBX. Refer to Table A-7 on page 49 for the E1 pinouts. Refer to Table A-7 on page 47 for the G.703 pinouts. Refer to Table A-10 on page 49 for the DBU connector pinout.
Option Modules NetVanta 4305 Hardware Installation Guide NetVanta Octal T1 Wide NIM (P/N 1200843L1) The NetVanta Octal T1 Wide NIM (shown in Figure 10) provides eight T1 (full T1 or fractional T1) WAN interfaces. Refer to Table A-4 on page 46 for the T1 interface pinout. Figure 10. NetVanta Octal T1 Wide NIM Features and Specifications Operating Modes • • T1/FT1 Frame Relay T1/FT1 PPP T1/FT1 Interface • • • • • • • Line Rate: 1.
NetVanta 4305 Hardware Installation Guide Option Modules Dial Backup Interface Modules NetVanta Analog Modem DIM (P/N 1200864L1) The Analog Modem DIM provides a modem with data rates up to 33.6 kbps for the NetVanta 4305. This DIM is a plug-on card that connects to the NIM. For installation instructions, see Installing Dial Backup and Network Interface Modules on page 41. Features and Specifications Features • • ITU V.
Option Modules NetVanta 4305 Hardware Installation Guide NetVanta ISDN BRI DIM (P/N 1200865L1) The NetVanta ISDN BRI DIM provides dial backup access to the public switched telephone network (PSTN) via Basic Rate ISDN for the NetVanta 4305. This DIM is a plug-on module that connects to the NIM. For installation instructions, see Installing Dial Backup and Network Interface Modules on page 41.
NetVanta 4305 Hardware Installation Guide Option Modules NetVanta ISDN S/T DIM (P/N 1200875L1) The NetVanta ISDN S/T DIM provides dial backup access to the public switched telephone network (PSTN) via Basic Rate ISDN for the NetVanta 4305. This DIM is a plug-on module that connects to the NIM. For installation instructions, see Installing Dial Backup and Network Interface Modules on page 41.
Unit Installation 4. NetVanta 4305 Hardware Installation Guide UNIT INSTALLATION The instructions and guidelines provided in this section cover hardware installation topics such as wall mounting/rack mounting the unit and installing option cards.
NetVanta 4305 Hardware Installation Guide Unit Installation Mounting Options If you have purchased the VPN Accelerator Card, install it first. See Installing the NetVanta VPN Accelerator Card (1202368L1) on page 43. The NetVanta 4305 may be installed in a tabletop, wall mount, or 19-inch rack mount configuration. The following sections provide step-by-step instructions for rack mounting and wall mounting.
Unit Installation NetVanta 4305 Hardware Installation Guide Instructions for Wall Mounting NetVanta 4305 (Continued) Step Action 4 Have someone else hold the unit in position as you install two 3/ 32" to 1/ 8" (1 1/ 2" or greater in length) wood screws through the unit’s brackets and into the mounted board. 5 Proceed to the steps given in Supplying Power to the Unit on page 40. Supplying Power to the Unit As shipped, each NetVanta 4305 is set to factory default conditions.
NetVanta 4305 Hardware Installation Guide Unit Installation Installing Dial Backup and Network Interface Modules The DIMs plug on to the NIMs. The NIMs are then installed in the rear panel option module slot. The following tables list the installation steps. See Figure 11 below and Figure 12 on page 42. Always remove power from the unit prior to removing or installing a module. Improper installation may result in damage to the modules.
Unit Installation NetVanta 4305 Hardware Installation Guide Instructions for Installing the NIMs and Wide NIMs Step Action 1 Remove power from the unit. 2 Slide the option module into the option slot until the module is firmly seated against the front of the chassis. 3 Secure the pins at both edges of the module. 4 Connect the cables to the associated device(s). 5 Restore power to the unit.
NetVanta 4305 Hardware Installation Guide Unit Installation Installing the NetVanta VPN Accelerator Card (1202368L1) The optional VPN Accelerator Card plugs into a 32-bit PCI slot and is designed to be used in the NetVanta 4305 to provide encryption/decryption and security acceleration services. The card provides the following security services to the host processor: DES, Triple-DES, AES, SHA-1, MD5, and Random Number Generation. Performance metrics include 528 Mbps-DES, 176 Mbps-3DES, and 422 Mbps-AES.
Unit Installation 44 NetVanta 4305 Hardware Installation Guide © 2004 ADTRAN, Inc.
APPENDIX A. CONNECTOR PIN DEFINITIONS The following tables provide the pin assignments for the base unit, network interface modules (NIMs), and dial backup interface modules (DIMs). Base Unit Pinouts Table A-1. 10/100BaseT Ethernet Port Pinouts Pin Name Description 1 TX1 Transmit Positive 2 TX2 Transmit Negative 3 RX1 Receive Positive 4,5 — Unused 6 RX2 Receive Negative 7,8 — Unused Table A-2.
Appendix A. Connector Pin Definitions NetVanta 4305 Hardware Installation Guide Network Interface Module (NIM) and Wide NIM Pinouts Table A-3. WAN-DDS Connector Pinouts Pin Name Description 1 R1 Transmit data to the network—Ring 1 2 T1 Transmit data to the network—Tip 1 3-6 — Unused 7 T Receive data from the network—Tip 8 R Receive data from the network—Ring Table A-4.
NetVanta 4305 Hardware Installation Guide Appendix A. Connector Pin Definitions Table A-6. DSX-1 Connector Pinout Pin Name Description 1 R Transmit data toward the DTE—Ring 2 T Transmit data toward the DTE—Tip 3 — Unused 4 R1 Receive data from the DTE—Ring 1 5 T1 Receive data from the DTE—Tip 1 6-8 — Unused Table A-7. G.
Appendix A. Connector Pin Definitions NetVanta 4305 Hardware Installation Guide Table A-8. Serial NIM Connector Pinouts Pin Name Pin Name 1 TD_A 14 TD_B 2 ETC_A 15 ETC_B 3 TCLK_A 16 TCLK_B 4 RCLK_A 17 RCLK_B 5 RD_A 18 RD_B 6 DCD_A 19 Unused 7 DTR_A 20 Unused 8 RTS_A 21 Unused 9 RTS_B (V.11 only) 22 Unused 10 CTS_B (V.11 only) 23 Unused 11 CTS_A 24 Unused 12 DSR_A 25 Unused 13 TM_A 26 Ground 48 © 2004 ADTRAN, Inc.
NetVanta 4305 Hardware Installation Guide Appendix A. Connector Pin Definitions Dial Backup (DBU) Connectors Table A-9 describes the pinouts for the following modules: 56/64K, T1/FT1 (1st generation), and T1/ FT1+DSX-1 (1st generation). Table A-9. DBU Connector Pinouts Pin Name Description 1 R1 Network–Ring 1 2 T1 Network—Tip 1 3 — Unused 4 T Network–Tip 5 R Network–Ring 6-8 — Unused Table A-10 describes the pinouts for the following modules: Serial, E1/FE1, E1/FE1 with G.
Appendix A. Connector Pin Definitions 50 NetVanta 4305 Hardware Installation Guide © 2004 ADTRAN, Inc.
NetVanta 4305 Hardware Installation Guide Numerics 10/100BaseT Ethernet 19 interface 45 pinout 45 56K/64K interface 19 A accelerator card 43 affidavits 8 C console port pinout 45 contents of shipment 20 D DBU interface 23, 49 pinout 23, 49 Dial Backup Interface Modules (DIMs) NetVanta Analog Modem DIM features and specifications 35 shipping contents 21 NetVanta ISDN BRI DIM features and specifications 36 shipping contents 21 NetVanta ISDN S/T DIM features and specifications 37 shipping contents 22 DIM inst
NetVanta 4305 Hardware Installation Guide LEDs 23 front panel 23 M mounting options rack 39 wall 39 N NET 1/NET 2 DBU LED 23 NET 1/NET 2 TD/RD LED 23 NET 1/NET 2 WAN LED 23 NetVanta 4305 features and specifications 19 front panel 23 installation 38 rear panel 25 shipping contents 20 NetVanta VPN Accelerator Card installation 43 shipping contents 22 Network Interface Modules (NIMs) 27 NetVanta 56K/64K NIM features and specifications 27 shipping contents 20 NetVanta Dual T1/E1 NIM features and specifications
NetVanta 4305 Hardware Installation Guide O option modules 26 P pinouts 10/100BaseT Ethernet 45 console port 45 DBU 23, 49 DSX-1 47 G.