Quarter Hour PM Thresholds Menu
The Quarter Hour PM Thresholds menu (see Figure 5-51) displays DS1 performance
monitoring thresholds data in a tabular format. This menu is used to set the performance
monitoring threshold levels and enable or disable alarms if the thresholds are exceeded.
Figure 5-51. Quarter Hour PM Thresholds Menu
The Quarter Hour PM Thresholds menu options are listed in Table 5-38.
Table 5-38. Quarter Hour PM Thresholds Menu Options
Option Description Function
1 ES-L This option sets the ES-L threshold value. The available
threshold range is (1-900). The default value is 65.
2 CV-P (ESF mode) This option sets the CV-P ESF threshold value. The available
threshold range is (1-16383). The default value is 13,296.
3 CV-P (SF mode) This option sets the CV-P SF threshold value. The available
threshold range is (1-16383). The default value is 72.
4 ES-P This option sets the ES-P threshold value. The available
threshold range is (1-900). The default value is 65.
5 SES-P This option sets the SES-P threshold value. The available
threshold range is (1-900). The default value is 10.
6 SAS-P This option sets the SAS-P threshold value. The available
threshold range is (1-900). The default value is 2.
7 CSS-P This option sets the CSS-P threshold value. The available
threshold range is (1-900). The default value is 72.
MX410 MM/DD/YY HH:MM
Active Alarms: CRITICAL MAJOR ID: MX410
Quarter Hour PM Thresholds
Threshold Alarm
1 - ES-L : 65 Enabled
2 - CV-P (ESF mode) : 13296 Enabled
3 - CV-P (SF mode) : 72 Enabled
4 - ES-P : 65 Enabled
5 - SES-P : 10 Enabled
6 - SAS-P : 2 Enabled
7 - CSS-P : 1 Enabled
8 - UAS-P : 10 Enabled
9 - Restore ALL DS1 Threshold Defaults
10 - Enable ALL DS1 Threshold Alarms
11 - Disable ALL DS1 Threshold Alarms