Specifications
MX410/MX412 System Manual
5-58 61189500L1-1F
Test Menu
The Test menu (see Figure 5-43) provides options for testing the DS1 Ports.
Figure 5-43. Test Menu
The Test menu options are listed in Table 5-31.
Note: The numbers in parenthesis “()” in the Option column denote the option numbers for the MX412 system.
Table 5-31. Test Menu Options
Option Description Function
1-4
(1-12)
1-4 (1-12 for MX412) This option is used to invokes the “DS1 (Port #) Menu” on
page 5-59.
5
(13)
Reset ALL Tests This option is used to stop all DS1 port testing and resets all
DS1 ports to Data Mode.
6
(14)
Loopback Timeout This option is used to set the loopback timeout value. The
default value is 120 Minutes and the possible values are as
follows:
• 120 Minutes
• 90 Minutes
• 60 Minutes
• 30 Minutes
• 15 Minutes
• 10 Minutes
• 5 Minutes
• Disabled
MX410 MM/DD/YY HH:MM
Active Alarms: CRITICAL MAJOR ID: MX410
Test
DS1 Ports
1 - #1 : Pattern
2 - #2 : Data mode
3 - #3 : Data mode
4 - #4 : Data mode
5 - Reset ALL Tests
6 - Loopback Timeout: 120 Minutes
Selection : '?' - System Help Screen