Specifications

MX3216 System Manual
4-12 61189008L1-1B
Installing the MX3RMM
The MX3RMM occupies an expansion slot in the MX3 chassis. Follow the steps listed to install
the MX3RMM used with remote management applications. Figure 4-9 illustrates the
installation of the MX3RMM.
1. If present, remove the blank plug (P/N 1189006L1) from the appropriate expansion slot.
NOTE
A blank plug must be installed in the empty expansion slot.
2. Open the ejector latch on the left side of the MX3RMM front panel.
3. Gently, but firmly, slide the MX3RMM into the upper (
B) or lower (A) expansion slot,
taking note of the left and right guide grooves in the chassis. Simultaneously, apply
thumb pressure on the left (on the ADTRAN logo) and right (to the right of
PORT 4) of the
MX3RMM to ensure a good seat of the MX3RMM pins into the backplane connector.
4. Push the ejector latch against the front panel until it latches.
The MX3RMM initializes and begins a self-test upon insertion into an active MX3 chassis.
When the self-test completes, the LEDs reflect the true state of the MX3RMM (see Table 1-4).
Figure 4-9. MX3RMM Installation
B
A