Specifications
Section 3, Application Guidelines - MX3216 Data Path Block Diagram
61189008L1-1B 3-3
Drop and Continue Application
In the drop and continue application, up to eight DS1s from one DS3 can be dropped out the
eight DSX-1 ports with the remaining DS1s continuing through to the other DS3 interface (see
Figure 3-2). This allows one DS3 worth of bandwidth to deliver DS1s to several sites using one
MX3216 at each site.
Figure 3-2. Drop and Continue Application Diagram
Table 3-1 shows the equipment needed for a drop and continue application.
Table 3-1. Drop and Continue Application - Required Equipment
Part # Equipment Quantity
1189001L1 MX3 Chassis 1
1189007L1 MX3 Fan Module 1
1189008L1 MX3216 Controller Card 1 (2 for redundancy)