Specifications

Section 2, Engineering Guidelines - Compliance
61189008L1-1B 2-7
COMPLIANCE
The MX3216 system complies with NEBS Level 3 and is NRTL Listed to UL 60950. It is
intended to be installed in a restricted access area only.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes and modifications not expressly approved by ADTRAN could void the user’s authority
to operate this equipment.
CAUTION
Per GR-1089-CORE October 2002, Section 9, this system is
designed and intended only for installation in a DC-C (common)
Bonding and Grounding system. It is not intended or designed for
installation in a DC-I (isolated) Bonding and Grounding system.
The ground wire must be of equal or greater ampacity than the wire
connected to the VDC return.
CAUTION
The MX3216 Controller Card must be installed in a MX3 chassis
(P/N 1189001L1) with a top assembly revision of “B” or later.
Table 2-9, Table 2-10, Table 2-11 and Table 2-12 provide the compliance codes for the
different components of the MX3216 system.
Table 2-9. MX3 Chassis (P/N 1189001L1)
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) X
Installation Code (IC) A
Table 2-10. MX3 Remote Management Module (P/N 1189004L1)
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC)
Installation Code (IC) A