Specifications
MX3216 System Manual
2-6 61189008L1-1B
DSX-1 CONNECTIONS
WARNING
Do not metallically connect the T/R (DSX-1) interfaces to interfaces
which connect to the Outside Plant (OSP) or its wiring. These inter
-
faces are designed for use as intra-building interfaces only. The
addition of Primary Protectors is not sufficient protection in order
to connect these interfaces metallically to OSP wiring.
Table 2-8 provides the amphenol connector pin assignments for the MX3216 Controller Card.
Table 2-8. Amphenol Connector Pin List
Function
Pin Tip (In) Ring (Out) Pin
1 Tip 1 Ring 1 33
2 Tip 2 Ring 2 34
3 Tip 3 Ring 3 35
4 Tip 4 Ring 4 36
5 Tip 5 Ring 5 37
6 Tip 6 Ring 6 38
7 Tip 7 Ring 7 39
8 Tip 8 Ring 8 40
9 Tip 9 Ring 9 41
10 Tip 10 Ring 10 42
11 Tip 11 Ring 11 43
12 Tip 12 Ring 12 44
13 Tip 13 Ring 13 45
14 Tip 14 Ring 14 46
15 Tip 15 Ring 15 47
16 Tip 16 Ring 16 48
32 FGND FGND 64