Specifications

MX3216 System Manual
2-4 61189008L1-1B
POWER DISSIPATION
The following two sections detail the power dissipation requirements for the MX3216
Controller Card, the MX3RMM, and the MX3216 system.
Module Configurations
Table 2-5 provides the heat dissipation data for each module at –48 VDC (operating range of
–42 VDC to –60 VDC) and ±24 VDC (operating range of ±22 VDC to ±27 VDC).
System Configurations
Table 2-6 provides the total heat dissipation at –48 VDC and ±24 VDC for the different
MX3216 system configurations.
Table 2-5. Heat Dissipation
Part Number Equipment Heat Dissipation
at –48 VDC
Heat Dissipation
at ±24 VDC
1189004L1 MX3RMM 3.0 watts 3.0 watts
1189007L1 MX3 Fan Module 2.39 watts 2.28 watts
1189008L1 MX3216 14.4 watts 14.2 watts
1189008L1 MX3216 (redundant pair) 21.6 watts 21.6 watts
Table 2-6. Total Heat Dissipation
Part Number Quantity Total Heat Dissipation
at –48 VDC
Total Heat Dissipation
at ±24 VDC
MX3216 (non-redundant) with one MX3RMM
1189004L1 1
16.2 watts 14.1 watts1189007L1 1
1189008L1 1
MX3216 (redundant) with one MX3RMM
1189004L1 1
24.0 watts 20.3 watts1189007L1 1
1189008L1 2