Specifications

MX3216 System Manual
6-60 61189008L1-1B
Status Menu
The Status menu (see Figure 6-40) presents a condensed version of the system status for the
MX3216. More detailed information is available through the options.
Figure 6-40. Status Menu
The Status menu Options are shown in Table 6-34.
Table 6-34. Status Menu Options
Option Description Function
1 Controller Equipment This option displays the “Controller Equipment
Screen” on page 6-62. The Controller Equipment
screen provides the controller card status and
alarm conditions.
2–3 DS3 A/B This option displays the “DS3 Status Menu” on
page 6-64. The DS3 A/B Status screen provides the
DS3 status, test, alarm, and mapping information.
4 DS1 Ports This option displays the “DS1 Ports Screen” on
page 6-68. The DS1 Ports screen displays status
and test information for the DSX-1 ports.
5 Environmental Alarms This option displays the “Environmental Alarms
Screen” on page 6-70. The Environmental Alarms
screen displays the environmental alarms and ACO
status.
Card: Controller A ADTRAN MX3216 System MM/DD/YY hh:mm
Unacknowledged Alarms: NONE ID: Site 1 MX3216
MX3216->Status
1 - Controller Equipment 4 - DS1 Ports
Active (Card A) : Normal <1-4> : OFF OFF OFF OFF
Standby (Card B) : Not Installed <5-8> : OFF OFF OFF OFF
<9-12> : OFF OFF OFF OFF
2 - DS3 A (DS3 A) <13-16> : OFF OFF OFF OFF
State : Normal
Status : OK 5 - Environmental Alarms
State : Major
3 - DS3 B (DS3 B)
State : DS3-ALARM 6 - MX3RMM
Status : LOS OOF DS2-OOF State : Normal
Module B
State : Not Installed
Fan Module
State : Normal
Selection : '?' - System Help Screen