Unit installation

61223026L2-5A Issue 1, November 2003 13
Abbreviations used in the Performance History Screens
are defined in the
Data Definitions (Figure 14 and
Figure 15).
Figure 14. Performance Data Definitions Screen
Figure 15. Performance Data Definitions Screen (Continued)
CIRCUIT ID: 10/29/03 09:29:45
Press ESC to return to previous menu
Performance Data Definitions
H2TUC, H2TUR, and H2R LOOP Related: HDSL2 Framing
ES-L Errored Seconds CRC>=1 or LOSW>=1
SES-L Severely Errored Seconds CRC>=50 or LOSW>=1
UAS-L Unavailable Seconds >10 cont. SES-Ls
DS1 and DSX-1 Line Related: Superframe and Extended Superframe
ES-L Errored Seconds (BPV+EXZ)>=1 or LOS>= 1
SES-L Severely Errored Seconds (BPV+EXZ)>=1544 or LOS>=1
UAS-L Unavailable Seconds >10 cont. SES-Ls
PDVS-L Pulse Density Violation Secs EXZ>=1; >7 zeros if B8ZS, >15 if AMI
B8ZS-L B8ZS Seconds B8ZS coded signal received
CV-L Code Violation Count (BPV+EXZ) count
NOTE: Reverse video indicates invalid data due to a terminal restart (or power
cycle), a data register reset, or a system date or time change.
N. Next
P. Previous Selection:
CIRCUIT ID: 10/29/03 09:29:45
Press ESC to return to previous menu
Performance Data Definitions
DS1 and DSX-1 Path Related: Superframe Extended Superframe
ES-P Errored Seconds FE>=1 or CRC>=1 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
SES-P Severely Errored Seconds FE>=8 or CRC>=320 or
SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
UAS-P Unavailable Seconds >10 cont. SES-Ps >10 cont. SES-Ps
SAS-P SEF/AIS Seconds SEF>=1 or AIS>=1 SEF>=1 or AIS>=1
ES-PFE Far End Errored Seconds n/a PRM bits G1-G6,SE,
or SL=1, or RAI
CV-P Code Violation Count FE count CRC error count
NOTE: Under a UAS-P condition, ES-P and SES-P counts are inhibited.
Under a SES-L or SES-P condition, the respective CV-L or CV-P count is
inhibited.
P. Previous Selection: